MSFT_SIPLogSetting
This content is no longer actively maintained. It is provided as is, for anyone who may still be using these technologies, with no warranties or claims of accuracy with regard to the most recent product version or service release.
Allows you to enable call detail recording or Quality of Experience (QoE) monitoring for servers in this pool.
The property values for the MSFT_SIPLogSetting class map to the settings found on the Monitoring tab of the Front End Properties dialog box. You can access these values in the Office Communications Server 2007 R2 Administration Tool by right-clicking the name of a Standard Edition server or Enterprise Edition pool, pointing to Properties, and then clicking Front End Properties. In the Front End Properties dialog box, click the Monitoring tab. Note that these settings apply only to the specified pool or server.
MSFT_SIPLogSetting
The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties. Properties are listed in alphabetic order, not MOF order.
Syntax
class MSFT_SIPLogSetting
{
[key] string Backend;
boolean Critical;
boolean EnableCDR;
boolean Enabled;
boolean EnableQMS;
[key] string InstanceID;
uint32 QoETimeToBeReceived;
uint32 QoETimeToReachQueue;
uint32 TimeToBeReceived;
uint32 TimeToReachQueue;
};
Methods
This class does not define any methods.
Properties
The MSFT_SIPLogSetting class has the following properties.
Backend
Data type: [key] stringAccess type: Read-only
Required: When accessing data from any role that belongs to a pool. This property must be empty when accessing data from the Edge Server or Proxy Server role.
This property identifies the instance of SQL Server that manages the back-end database for Office Communications Server.
The value for this property depends on the topology of Office Communications Server.
Topology
Value
Standard Edition
(local)\rtc
Enterprise Edition
(consolidated or expanded configuration)
computername\instancename
or
computername
For Enterprise Edition, computername identifies either the FQDN or the NetBIOS name of the host computer for SQL Server and instancename identifies a named instance of SQL Server on the host computer. The value computername by itself specifies the default instance of SQL Server on the host computer.
The Backend property does not map to the Front End Server Properties dialog box.
Critical
Data type: booleanAccess type: Read/Write
Required. Controls whether the server shuts down if an instant message cannot be archived.
If True, Office Communications Server shuts down if this extension module (the IM Archiving Agent) fails. If False, Office Communications Server continues running despite extension module failure.
The default value is False.
The Critical property does not map to the Front End Server Properties dialog box.
EnableCDR
Data type: booleanAccess type: Read/Write
Required. Controls whether CDR is enabled in the pool.
The default value is False.
The EnableCDR property maps to the Enable call detail recording (CDR) checkbox in the Front End Properties dialog box.
Enabled
Data type: booleanAccess type: Read/Write
Required. Controls whether the IM Archiving Agent is enabled.
If True, the IM Archiving Agent is enabled on Office Communications Server; if False, it is not.
The default value is False.
The Enabled property does not map to the Front End Server Properties dialog box.
EnableQMS
Data type: booleanAccess type: Read/Write
Required. Controls whether QoE is enabled in the pool.
The default value is False.
The EnableQMS property maps to the Enable QoE monitoring checkbox in the Front End Properties dialog box.
InstanceID
Data type: [key] stringAccess type: Read-only. A GUID value that uniquely identifies an instance of this class.
The GUID must be encapsulated between the "{" and "}" braces; for example: "{01234567-0123-4567-89AB-CDEF01234567}".
The InstanceID property does not map to the Front End Server Properties dialog box.
QoETimeToBeReceived
Data type: uint32Access type: Read/Write
Required. Specifies the number of minutes before throwing an error event that the QoE agent waits for a message to be sent after it reaches the destination queue.
The minimum value for this property is 0 and the maximum value is 1440.
The default value is 45.
The QoETimeToBeReceived property does not map to the Front End Server Properties dialog box.
QoETimeToReachQueue
Data type: uint32Access type: Read/Write
Required. Specifies the number of minutes before throwing an error event that the QoE agent waits for a message to reach the destination.
The minimum value for this property is 0 and the maximum value is 1440.
The default value is 30.
The QoETimeToReachQueue property does not map to the Front End Server Properties dialog box.
TimeToBeReceived
Data type: uint32Access type: Read/Write
Required. Specifies the number of minutes for the Archiving agent to wait for a message to be archived after reaching the destination queue before stopping the Office Communications Server service when Critical is set to True.
The minimum value for this property is 0 and the maximum value is 1440.
The default value is 45.
The TimeToBeReceived property does not map to the Front End Server Properties dialog box.
TimeToReachQueue
Data type: uint32Access type: Read/Write
Required. Specifies the number of minutes for the Archiving agent to wait for a message to reach the destination queue before stopping the Office Communications Server service when Critical is set to True.
The minimum value for this property is 0 and the maximum value is 1440.
The default value is 30.
The TimeToReachQueue property does not map to the Front End Server Properties dialog box.
Remarks
This class gets and sets information at the following level: SQL.
Changes to the value of TimeToBeReceived or TimeToReachQueue does not take effect until the Office Communications Server Front End service is restarted.
Only one instance of this class can be present in the pool.
Instances of this class support the following interface methods:
Provider::EnumerateInstances();
Provider::GetObject();
Provider::PutInstance();
Where PutInstance() supports the following flags:
WBEM_FLAG_CREATE_ONLY
WBEM_FLAG_UPDATE_ONLY
WBEM_FLAG_CREATE_OR_UPDATE
Requirements
Server: Installed on computers serving the following roles: Administrative Tools Server and Front End Server.
Namespace: Defined in \root\cimv2.