Teilen über


CLUSCTL_NODE_SET_COMMON_PROPERTIES control code

Updates the read/write common properties for a node. Applications use this control code as a ClusterNodeControl parameter.

ClusterNodeControl( hNode,                                             // node handle
                    hHostNode,                                         // optional host node
                    CLUSCTL_NODE_SET_COMMON_PROPERTIES,                // this control code
                    lpInBuffer,                                        // input buffer: property list
                    cbInBufferSize,                                    // allocated buffer size (bytes)
                    NULL,                                              // output buffer (not used)
                    0,                                                 // output buffer size (not used)
                    NULL );                                            // actual size of resulting data (not used)

Parameters

The following control code function parameter is specific to this control code. For complete parameter descriptions, see ClusterNodeControl.

lpInBuffer

Pass a pointer to a property list containing new values for one or more read/write common node properties.

Return value

ClusterNodeControl returns one of the following values.

ERROR_SUCCESS

0

The operation completed successfully. The property list is correctly formatted and contains valid data values.

ERROR_INSUFFICIENT_BUFFER

122 (0x7A)

The data area passed to a system call is too small. The actual size of the property list buffer as determined by the Cluster service is larger than the size specified in the cbInBufferSize parameter.

ERROR_INVALID_DATA

13 (0xD)

The data is invalid. The property list is either formatted incorrectly or contains invalid data, such as an out-of-range value.

ERROR_INVALID_PARAMETER

87 (0x57)

The data is invalid.

RPC_X_BAD_STUB_DATA

1783 (0x6F7)

The stub received bad data. The lpInBuffer parameter is NULL.

System error code

If any other value is returned, then the operation failed.

Remarks

For information on working with property lists, see Using Property Lists.

ClusAPI.h defines the 32 bits of CLUSCTL_NODE_SET_COMMON_PROPERTIES as follows (for more information, see Control Code Architecture).

Component Bit location Value
Object code
24 31
CLUS_OBJECT_NODE (0x4)
Global bit
23
CLUS_NOT_GLOBAL (0x0)
Modify bit
22
CLUS_MODIFY (0x1)
User bit
21
CLCTL_CLUSTER_BASE (0x0)
Type bit
20
External (0x0)
Operation code
0 23
CLCTL_SET_COMMON_PROPERTIES (0x40005e)
Access code
0 1
CLUS_ACCESS_WRITE (0x2)

Requirements

Minimum supported client
None supported
Minimum supported server
Windows Server 2008 Enterprise, Windows Server 2008 Datacenter
Header
ClusAPI.h

See also

Node Control Codes

ClusterNodeControl