ConnectorFrameworkProxy.AcknowledgeMonitoringAlerts Method (Guid, DateTime)
Applies To: Operations Manager for System Center 2012
The monitoring connector acknowledges that it has successfully received monitoring alerts from the ConnectorFrameworkProxy. It acknowledges alerts that occur until the given bookmark time.
Namespace: Microsoft.EnterpriseManagement.ConnectorFramework
Assembly: Microsoft.EnterpriseManagement.OperationsManager (in Microsoft.EnterpriseManagement.OperationsManager.dll)
Syntax
public void AcknowledgeMonitoringAlerts(
Guid connectorId,
DateTime utcBookmarkTime
)
public:
void AcknowledgeMonitoringAlerts(
Guid connectorId,
DateTime utcBookmarkTime
)
member AcknowledgeMonitoringAlerts :
connectorId:Guid *
utcBookmarkTime:DateTime -> unit
Public Sub AcknowledgeMonitoringAlerts (
connectorId As Guid,
utcBookmarkTime As Date
)
Parameters
connectorId
Type: System.GuidA globally unique identifier (GUID) for the monitoring connector.
utcBookmarkTime
Type: System.DateTimeA timestamp bookmark.
Remarks
The monitoring connector must acknowledge that alerts have been received. Failure to acknowledge an alert will result in subsequent calls to GetMonitoringAlerts returning alerts that have already been returned.
After acknowledging alerts, you get alerts that are updated after the bookmark time that you acknowledged with.
Use server time rather than the current client time for the bookmark time. Choose the maximum time of the alerts you are acknowledging. Use the maximum value of the LastModified property to ensure no data loss.
See Also