Hinweis
Für den Zugriff auf diese Seite ist eine Autorisierung erforderlich. Sie können versuchen, sich anzumelden oder das Verzeichnis zu wechseln.
Für den Zugriff auf diese Seite ist eine Autorisierung erforderlich. Sie können versuchen, das Verzeichnis zu wechseln.
Verifies that a property list is properly formatted. Applications use this control code as a ClusterNetworkControl parameter.
ClusterNetworkControl( hNetwork, // network handle
hHostNode, // optional host node
CLUSCTL_NETWORK_VALIDATE_PRIVATE_PROPERTIES, // this control code
lpInBuffer, // input buffer: property list
cbInBufferSize, // allocated buffer size (bytes)
NULL, // output buffer (not used)
0, // output buffer size (not used)
NULL ); // actual size of resulting data (not used)
Parameters
The following control code function parameter is specific to this control code. For complete parameter descriptions, see ClusterNetworkControl.
-
lpInBuffer
-
Pass a pointer to a property list containing one or more read/write network private properties.
Return value
ClusterNodeControl returns one of the following values.
-
ERROR_SUCCESS
-
0
The operation completed successfully. The property list is correctly formatted and contains valid data values.
-
ERROR_INSUFFICIENT_BUFFER
-
122 (0x7A)
The data area passed to a system call is too small. The actual size of the property list buffer as determined by the Cluster service is larger than the size specified in the cbInBufferSize parameter.
-
ERROR_INVALID_DATA
-
13 (0xD)
The data is invalid. The property list is either formatted incorrectly or contains invalid data, such as an out-of-range value.
-
ERROR_INVALID_PARAMETER
-
87 (0x57)
The parameter is incorrect.
-
RPC_X_BAD_STUB_DATA
-
1783 (0x6F7)
The stub received bad data. The lpInBuffer parameter is NULL.
-
If any other value is returned, then the operation failed.
Remarks
By default, failover clusters do not define any private properties for networks.
ClusAPI.h defines the 32 bits of CLUSCTL_NETWORK_VALIDATE_PRIVATE_PROPERTIES as follows (for more information, see Control Code Architecture).
Component | Bit location | Value |
---|---|---|
Object code |
24 31 |
CLUS_OBJECT_NETWORK (0x5) |
Global bit |
23 |
CLUS_NOT_GLOBAL (0x0) |
Modify bit |
22 |
CLUS_NO_MODIFY (0x0) |
User bit |
21 |
CLCTL_CLUSTER_BASE (0x0) |
Type bit |
20 |
External (0x0) |
Operation code |
0 23 |
CLCTL_VALIDATE_PRIVATE_PROPERTIES (0x89) |
Access code |
0 1 |
CLUS_ACCESS_READ (0x1) |
Requirements
Minimum supported client |
None supported |
Minimum supported server |
Windows Server 2008 Enterprise, Windows Server 2008 Datacenter |
Header |
|