Edit

How to Enable or Disable Software Metering

You enable or disable the Software Metering Client Agent, in Configuration Manager, by modifying the site control file settings.

Tip

For additional information on changing client settings, see How to Apply Custom Client Settings.

To enable or disable the software metering client agent

  1. Set up a connection to the SMS Provider.

  2. Make a connection to the Software Metering Client Agent section of the site control file by using the SMS_SCI_ClientComp class.

  3. Loop through the array of available properties, making changes as needed.

  4. Commit the changes to the site control file.

Example

The following example method enables or disables the Software Metering Client Agent by using the SMS_SCI_ClientComp class to connect to the site control file and change properties.

For information about calling the sample code, see Calling Configuration Manager Code Snippets.


Sub EnableDisableSWMClientAgent(swbemServices,     _
                                swbemContext,      _
                                enableDisableFlag, _
                                siteToChange )

    ' Load site control file and get SWM client component section.
    swbemServices.ExecMethod "SMS_SiteControlFile.Filetype=1,Sitecode=""" & siteToChange & """", "Refresh", , , swbemContext
    Set objSWbemInst = swbemServices.Get("SMS_SCI_ClientComp.Filetype=1,Itemtype='Client Component',Sitecode='" & siteToChange & "',ItemName='Software Metering Agent'", , swbemContext)

    ' Display SWM client agent settings before change
    Wscript.Echo " "
    Wscript.Echo "Properties - Before Change"
    Wscript.Echo "---------------------------"
    Wscript.Echo objSWbemInst.ClientComponentName
    Wscript.Echo objSWbemInst.Flags & " (0 = Disabled, 1 = Enabled)"

    ' Set SWM client agent by setting Flags value to  0 or 1 using the enableDisableFlag variable.
    objSWbemInst.Flags = enableDisableFlag

    ' Save new client agent settings.
    objSWbemInst.Put_ , swbemContext
    swbemServices.ExecMethod "SMS_SiteControlFile.Filetype=1,Sitecode=""" & siteToChange & """", "Commit", , , swbemContext

    ' Refresh in-memory copy of the site control file and get the client component section.
    swbemServices.ExecMethod "SMS_SiteControlFile.Filetype=1,Sitecode=""" & siteToChange & """", "Refresh", , , swbemContext
    Set objSWbemInst = swbemServices.Get("SMS_SCI_ClientComp.Filetype=1,Itemtype='Client Component',Sitecode='" & siteToChange & "',ItemName='Software Metering Agent'", , swbemContext)

    ' Display SWM client agent settings after change.
    Wscript.Echo " "
    Wscript.Echo "Properties - After Change"
    Wscript.Echo "---------------------------"
    Wscript.Echo objSWbemInst.ClientComponentName
    Wscript.Echo objSWbemInst.Flags & " (0 = Disabled, 1 = Enabled)"

End Sub


public void EnableDisableSWMClientAgent(WqlConnectionManager connection,
                                        string siteCode,
                                        string enableDisableFlag)

{
    try
    {
        IResultObject siteDefinition = connection.GetInstance(@"SMS_SCI_ClientComp.FileType=1,ItemType='Client Component',SiteCode='" + siteCode + "',ItemName='Software Metering Agent'");

        // Display client agent settings before changing the properties.
        Console.WriteLine();
        Console.WriteLine("Properties - Before Change");
        Console.WriteLine("---------------------------");
        Console.WriteLine(siteDefinition["ClientComponentName"].StringValue);
        Console.WriteLine(siteDefinition["Flags"].StringValue + " (0 = Disabled, 1 = Enabled)");

        // Set client agent by setting "Flags" value to 0 or 1 by using the enableDisableFlag variable.
        siteDefinition["Flags"].StringValue = enableDisableFlag;

        // Save the settings.
        siteDefinition.Put();

        // Verify the change by reconnecting and getting the value again.
        IResultObject siteDefinition2 = connection.GetInstance(@"SMS_SCI_ClientComp.FileType=1,ItemType='Client Component',SiteCode='" + siteCode + "',ItemName='Software Metering Agent'");

        // Display client agent settings after changing the properties.
        Console.WriteLine();
        Console.WriteLine("Properties - After Change");
        Console.WriteLine("--------------------------");
        Console.WriteLine(siteDefinition2["ClientComponentName"].StringValue);
        Console.WriteLine(siteDefinition2["Flags"].StringValue + " (0 = Disabled, 1 = Enabled)");
    }

    catch (SmsException ex)
    {
        Console.WriteLine("Failed. Error: " + ex.InnerException.Message);
        throw;
    }

}

The example method has the following parameters:

Parameter Type Description
connection - Managed: WqlConnectionManager
- VBScript: SWbemServices
A valid connection to the SMS Provider.
swbemContext - VBScript: SWbemContext A valid context object. For more information, see How to Add a Configuration Manager Context Qualifier by Using WMI.
siteCode - Managed: String
- VBScript: String
The site code.
enableDisableFlag - Managed: String
- VBScript: String
Determines whether the Software Metering Client Agent is enabled or disabled.

0 - Disabled

1 - Enabled

Compiling the Code

This C# example requires:

Namespaces

System

System.Collections.Generic

System.Text

Microsoft.ConfigurationManagement.ManagementProvider

Microsoft.ConfigurationManagement.ManagementProvider.WqlQueryEngine

Assembly

adminui.wqlqueryengine

microsoft.configurationmanagement.managementprovider

Robust Programming

For more information about error handling, see About Configuration Manager Errors.

.NET Framework Security

For more information about securing Configuration Manager applications, see Configuration Manager role-based administration.

See Also

Configuration Manager Software Development Kit About the Configuration Manager Site Control File How to Read and Write to the Configuration Manager Site Control File by Using Managed Code How to Read and Write to the Configuration Manager Site Control File by Using WMI SMS_SCI_Component Server WMI Class