Time Sync Not Working Accross Domain

austin221 1 Reputation point
2022-11-10T14:01:02.857+00:00

Hey everyone,

Late last week I decided to start using a time server to prevent time skew and drift across our domain. I pointed our primary domain controller to a few of the NIST time servers. Everything seemed good at first but it now seems that the other 3 domain controllers aren't syncing at all with the PDC, rather using the local CMOS clock. The workstations aren't syncing time with a DC either. My first guess is that some group policy was messing things up but I can't locate any policy that seems related. The PDC and is physical and the rest are VMs, no time is synced with any host.

  • Here's the configuration of the PDC:

[Configuration]

EventLogFlags: 2 (Local)
AnnounceFlags: 5 (Local)
TimeJumpAuditOffset: 28800 (Local)
MinPollInterval: 6 (Local)
MaxPollInterval: 10 (Local)
MaxNegPhaseCorrection: 172800 (Local)
MaxPosPhaseCorrection: 172800 (Local)
MaxAllowedPhaseOffset: 300 (Local)

FrequencyCorrectRate: 4 (Local)
PollAdjustFactor: 5 (Local)
LargePhaseOffset: 50000000 (Local)
SpikeWatchPeriod: 900 (Local)
LocalClockDispersion: 10 (Local)
HoldPeriod: 5 (Local)
PhaseCorrectRate: 7 (Local)
UpdateInterval: 100 (Local)

FileLogName: C:\Windows\Temp\w32time.log (Local)
FileLogEntries: 0-116 (Local)
FileLogSize: 268435456 (Local)

[TimeProviders]

NtpClient (Local)
DllName: C:\Windows\SYSTEM32\w32time.DLL (Local)
Enabled: 1 (Local)
InputProvider: 1 (Local)
AllowNonstandardModeCombinations: 1 (Local)
ResolvePeerBackoffMinutes: 15 (Local)
ResolvePeerBackoffMaxTimes: 7 (Local)
CompatibilityFlags: 2147483648 (Local)
EventLogFlags: 1 (Local)
LargeSampleSkew: 3 (Local)
SpecialPollInterval: 3600 (Local)
Type: NTP (Local)
NtpServer: time.nist.gov,0x1 time-a-g.nist.gov,0x1 time-a-wwv.nist.gov,0x1 time-a-b.nist.gov,0x1 (Local)

NtpServer (Local)
DllName: C:\Windows\SYSTEM32\w32time.DLL (Local)
Enabled: 1 (Local)
InputProvider: 0 (Local)
AllowNonstandardModeCombinations: 1 (Local)

  • Here's one of the other DCs: [Configuration]

EventLogFlags: 2 (Local)
AnnounceFlags: 10 (Local)
TimeJumpAuditOffset: 28800 (Local)
MinPollInterval: 6 (Local)
MaxPollInterval: 10 (Local)
MaxNegPhaseCorrection: 172800 (Local)
MaxPosPhaseCorrection: 172800 (Local)
MaxAllowedPhaseOffset: 300 (Local)

FrequencyCorrectRate: 4 (Local)
PollAdjustFactor: 5 (Local)
LargePhaseOffset: 50000000 (Local)
SpikeWatchPeriod: 900 (Local)
LocalClockDispersion: 10 (Local)
HoldPeriod: 5 (Local)
PhaseCorrectRate: 7 (Local)
UpdateInterval: 100 (Local)

[TimeProviders]

NtpClient (Local)
DllName: C:\Windows\SYSTEM32\w32time.DLL (Local)
Enabled: 1 (Local)
InputProvider: 1 (Local)
CrossSiteSyncFlags: 2 (Local)
AllowNonstandardModeCombinations: 1 (Local)
ResolvePeerBackoffMinutes: 15 (Local)
ResolvePeerBackoffMaxTimes: 7 (Local)
CompatibilityFlags: 2147483648 (Local)
EventLogFlags: 1 (Local)
LargeSampleSkew: 3 (Local)
SpecialPollInterval: 1024 (Local)
Type: NT5DS (Local)

NtpServer (Local)
DllName: C:\Windows\SYSTEM32\w32time.DLL (Local)
Enabled: 1 (Local)
InputProvider: 0 (Local)
AllowNonstandardModeCombinations: 1 (Local)

VMICTimeProvider (Local)
DllName: C:\Windows\System32\vmictimeprovider.dll (Local)
Enabled: 1 (Local)
InputProvider: 1 (Local)

Please let me know if there's anything else useful I can provide. I'd greatly appreciate any help!

Thank you!

Windows for business | Windows Server | User experience | Other
0 comments No comments
{count} votes

1 answer

Sort by: Most helpful
  1. Anonymous
    2022-11-10T14:05:32.933+00:00

    On the problem ones you can reset by running

    w32tm /unregister
    net stop w32time
    w32tm /register
    net start w32time
    w32tm /config /syncfromflags:domhier /update
    net stop w32time
    net start w32time
    then check
    w32tm /query /source