Important
Azure Stack HCI, version 22H2 will reach end of support on May 31, 2025. After this date:
- Monthly security and quality updates stop.
- Billing continues for version 22H2 systems.
- Your system keeps working, including registration and repair.
- Microsoft Support remains available only for upgrade assistance.
To stay supported and continue receiving updates, we recommend upgrading your operating system to version 23H2. If you're running an Azure Stack HCI, version 22H2 stretch cluster or managing Azure Local via System Center - Virtual Machine Manager, review the Supported workloads and configurations table for update timelines.
This article describes how to upgrade the Azure Stack HCI operating system (OS) via PowerShell. Supported upgrade paths include:
From OS version 20349.xxxx to 26100.xxxx.
From OS version 25398.xxxx to 26100.xxxx.
Important
- This article covers OS upgrades only. Do not proceed if solution upgrade is complete or Azure Local 2311.2 or later is deployed. To check if your system is already running the solution, run the
Get-StampInformation
cmdlet. If it returns output, your system is already running the solution, and you should skip these steps. - The solution upgrade isn't yet supported on OS version 26100.xxxx.
High-level workflow for the OS upgrade
The Azure Stack HCI OS update is available only via the Azure portal.
To upgrade the OS on your system, follow these high-level steps:
- Complete the prerequisites.
- Update registry keys.
- Install new OS using PowerShell.
- Check the status of the updates.
- After the OS is upgraded, perform post-OS upgrade steps.
Complete prerequisites
Make sure your Azure Local system is running either OS version 20349.3692 or OS version greater than 25398.1611.
Make sure the system is registered in Azure and all the machines in the system are healthy and online.
Make sure to shut down virtual machines (VMs). We recommend shutting down VMs before performing the OS upgrade to prevent unexpected outages and damages to databases.
Confirm that you have access to the Azure Local 2505 ISO file, which you can download from the Azure portal.
Consult your hardware OEM to verify driver compatibility. Confirm that all drivers compatible with Windows Server 2025 or Azure Stack HCI OS, 26100.xxxx are installed before the upgrade.
Make sure the Network Interface Card (NIC) driver currently installed on your system is newer than the version included by default (inbox) with Azure Stack HCI OS, version 26100.xxxx. The following table compares the current and recommended versions of NIC drivers for two manufacturers:
NIC manufacturer Inbox driver version Recommended latest compatible driver Intel 1.15.121.0 1.17.73.0 NVIDIA 24.4.26429.0 25.4.50020 Ensure the instance is properly registered. If the identity property is missing or doesn’t contain
type = "SystemAssigned"
, run the following command to repair the registration:Register-AzStackHCI -TenantId "<tenant_ID>" -SubscriptionId "<subscription_ID>" -ComputerName "<computer_name>" -RepairRegistration
You can verify the identity property in the Azure portal in resource's JSON or by running the following cmdlet:
Get-AzResource -Name <cluster_name> -ResourceGroupName <name of the resource group> -ResourceType "Microsoft.AzureStackHCI/clusters" -ExpandProperties
(Recommended) Enable Secure Boot on Azure Local machines before you upgrade the OS. To enable Secure Boot, follow these steps:
- Drain the cluster node.
- Restart the OS.
- Enter the BIOS/UEFI menu.
- Review the Boot or Security section of the UEFI configuration options Locate the Secure Boot option.
- Set the option to Enabled or On.
- Save the changes and restart your computer.
Consult with your hardware vendor for assistance if required.
Update registry keys
To ensure Resilient File System (ReFS) functions properly during and after OS upgrade, follow these steps on each machine in the system to update registry keys. Reboot each machine for the changes to take effect.
Set
RefsEnableMetadataValidation
to0
:Set-ItemProperty -Path "HKLM:\SYSTEM\CurrentControlSet\Control\FileSystem" -Name "RefsEnableMetadataValidation" -Value 0 -Type DWord -ErrorAction Stop
Restart the machine to apply changes. If ReFS volumes fail to come online after reboot and the
RefsEnableMetadataValidation
key is reset, toggle the key. SetRefsEnableMetadataValidation
to 1 and then back to 0. To check volume status, run theGet-ClusterSharedVolumeState
command.Update and verify that the registry keys have been applied on each machine in the system before moving to the next step.
Install new OS using PowerShell
To install the new OS using PowerShell, follow these steps:
Note
The following steps require the Cluster-Aware Updating (CAU) role to be installed and enabled on the system. For information on how to install and enable this feature on your Azure Local, see Cluster-Aware Updating overview.
Run the following cmdlets on every machine in the system.
Set-WSManQuickConfig Enable-PSRemoting
To test whether the system is properly set up to apply software updates using Cluster-Aware Updating (CAU), run the
Test-CauSetup
cmdlet, which notifies you of any warnings or errors:Test-CauSetup -ClusterName <System name>
Validate the hardware and settings by running the
Test-Cluster
cmdlet on one of the machines in the system. If any of the condition checks fail, resolve them before proceeding to the next step.Test-Cluster
Extract the contents of the ISO image and copy them to the local system drive on each machine. Ensure that the local path is the same on each machine. Then, update the
PathToSetupMedia
parameter with the local path to the ISO image.# Define ISO and destination paths $isoFilePath = "C:\SetupFiles\WindowsServer\ISOs\example.iso" $destinationPath = "C:\SetupFiles\WindowsServer\Files" # Mount the ISO file $iso = Mount-DiskImage -ImagePath $isoFilePath # Get the drive letter $driveLetter = ($iso | Get-Volume).DriveLetter # Create the destination directory New-Item -ItemType Directory -Path $destinationPath # Copy contents to the local directory Copy-Item -Path "${driveLetter}:\*" -Destination $destinationPath –Recurse # Dismount the ISO file Dismount-DiskImage -ImagePath $isoFilePath
Upgrade the system.
Invoke-CauRun –ClusterName <SystemName> -CauPluginName Microsoft.RollingUpgradePlugin -EnableFirewallRules -CauPluginArguments @{ 'WuConnected'='false';'PathToSetupMedia'='\some\path\'; 'UpdateClusterFunctionalLevel'='true'; } -ForceSelfUpdate -Force
Wait for the update to complete and check the status of the update.
Check the status of an update
To get the summary information about an update in progress, run the
Get-CauRun
cmdlet:Get-CauRun -ClusterName <SystemName>
Here's a sample output:
RunId : <Run ID> RunStartTime : 10/13/2024 1:35:39 PM CurrentOrchestrator : NODE1 NodeStatusNotifications : { Node : NODE1 Status : Waiting Timestamp : 10/13/2024 1:35:49 PM } NodeResults : { Node : NODE2 Status : Succeeded ErrorRecordData : NumberOfSucceededUpdates : 0 NumberOfFailedUpdates : 0 InstallResults : Microsoft.ClusterAwareUpdating.UpdateInstallResult[] }
Validate the health of your system by running the
Test-Cluster
cmdlet on one of the machines in the system. If any of the condition checks fail, resolve them before proceeding to the next step.Test-Cluster
Verify that the registry keys are still applied on each machine in the system before moving to the next step.
To check if the registry key exists:
Set-ItemProperty -Path "HKLM:\SYSTEM\CurrentControlSet\Control\FileSystem" -Name "RefsEnableMetadataValidation"
To reapply the registry keys if needed and reboot each machine for the changes to take effect:
Set-ItemProperty -Path "HKLM:\SYSTEM\CurrentControlSet\Control\FileSystem" -Name "RefsEnableMetadataValidation" -Value 0 -Type DWord -ErrorAction Stop
If the OS upgrade fails, run the following command to recover the CAU run:
Invoke-CauRun –ForceRecovery -Force
You're now ready to perform the post-OS upgrade steps for your system.
Known issues
If the system is configured with Network ATC prior to performing the OS upgrade, the Network ATC management intent may fail with error PhysicalAdapterNotFound
after upgrading the OS. For detailed steps on how to resolve this issue, see the Troubleshooting guide.