Use the unified Azure IoT SDK for .NET or C to provision a device, connect it to Azure IoT Hub with the MQTT v5 connection profile, and send telemetry. Start with a small JSON message and verify it at your downstream destination before adding custom topics or more complex payloads.
The inline examples use Device Provisioning Service (DPS) to provision the device with an existing X.509 certificate and get its assigned IoT Hub connection details. The device then connects to that hub and publishes telemetry over MQTT v5; telemetry doesn't pass through DPS.
For SDK selection and the shared connection model, see Unified Azure IoT SDKs. Use an MQTT v5-compatible preview release from Available SDKs. The following examples pin specific versions so that their APIs and commands are reproducible.
Prerequisites
- Complete hub setup and routing setup, including an enabled all-messages route. See routing endpoint requirements for your destination.
- An enabled X.509 enrollment in DPS that assigns the device to the intended hub.
- The DPS ID scope and a device certificate with its matching private key.
- A device clock and certificate trust configuration suitable for TLS.
- A destination reader ready to locate the test message.
The following examples use an existing device certificate for DPS onboarding and the subsequent hub connection. Certificate issuance during onboarding is a separate setup path. These examples don't create an enrollment or obtain a certificate for the device.
X.509 device authentication
IoT hubs with the MQTT v5 connection profile require X.509 certificates for device connectivity. The certificate can be issued by Microsoft or a third-party certificate authority. Direct SAS authentication isn't supported for these hub connections.
Don't disable server certificate or hostname validation. For endpoint selection and shared TLS requirements, see IoT Hub endpoints.
Keep private keys and certificate passwords out of source control. File-based credentials are useful for a local evaluation. Use the key protection supported by your device platform for production design.
Device Provisioning Service (DPS) onboarding and certificates
DPS onboarding and hub authentication are separate. A symmetric-key onboarding credential doesn't enable SAS authentication to an MQTT v5 hub; the device must obtain an operational X.509 certificate through a supported DPS issuance path. The examples here instead use an existing X.509 certificate for both connections. For language- and version-specific support, see Provisioning and authentication.
The CLI creation setting --disable-local-auth false allows service-side
SAS authentication. It doesn't enable SAS device connections or change the
X.509 requirement. The setup walkthrough keeps these
service and device credential choices separate.
Operational certificate issuance and renewal through DPS
For MQTT v5, operational certificate issuance and renewal go through DPS, not directly through the hub. ADR provides the issuing CA and certificate policy. Renewal requires the onboarding credential and a new certificate signing request. SDK support varies by language, version, and API surface; don't assume automatic renewal. See SDK certificate-management support and Configure certificate issuance through DPS. The inline examples in this article don't implement certificate issuance or renewal.
Certificate issuance samples
For sample code that requests an operational certificate during DPS provisioning, see the C and .NET samples. Each device uses an individual-enrollment symmetric key to authenticate to DPS, generates a private key and CSR, and requests an operational certificate. The subsequent MQTT v5 hub connection uses X.509; the symmetric key is only an onboarding credential.
Follow the repository's setup instructions before running its standard telemetry, direct methods, and twins scenario. The shared verifier checks direct-method responses, desired-to-reported property updates, and telemetry receipt at a standalone Event Hubs destination. See the .NET sample and C build and run instructions. These samples demonstrate initial issuance, not automatic certificate renewal.
The samples passed local builds and offline checks. Live Azure scenarios and clean-machine setup still require validation. Review the repository's prerequisites and validation limitations before running them.
Certificate trust and rollover
Follow the shared server certificate and certificate pinning guidance to maintain the device trust store.
Confirm the cloud configuration
Use the preview extension from hub setup. Before running the device application, read the DPS ID scope and enrollment:
az iot dps show --name "<DPS_NAME>" --resource-group "<RESOURCE_GROUP_NAME>" --query properties.idScope --output tsv
az iot dps enrollment show --dps-name "<DPS_NAME>" --resource-group "<RESOURCE_GROUP_NAME>" --enrollment-id "<REGISTRATION_ID>" --query "{registrationId:registrationId,status:provisioningStatus}" --output json
Use the returned ID scope as DPS_ID_SCOPE in the device configuration.
The enrollment must be enabled and match the certificate's onboarding identity.
An ID scope isn't the DPS resource ID or the hub hostname.
Confirm the linked resources by using Verify readiness. Cloud configuration alone doesn't prove provisioning or message delivery; the device SDK and destination reader provide those checkpoints.
Choose a payload for the first test
Use UTF-8 JSON with an explicit content type. Include a unique test identifier so that you can distinguish a current message from old destination data.
For shared payload and content-metadata guidance, see Create and read IoT Hub messages. The routing endpoint's Message format is a separate setting; see Verify the result.
The initial .NET and C examples use the standard telemetry client. A custom-topic publisher is a separate SDK operation; see Publish a custom-topic test message with .NET for an example that also sets MQTT v5 user properties.
.NET
This example targets Microsoft.Azure.Iot.Device 2.0.0-preview4 and .NET 10.
It sends one JSON message through the unified telemetry client.
Create the application
Run these commands in PowerShell:
dotnet new console --name HubTelemetry --framework net10.0
Set-Location HubTelemetry
dotnet add package Microsoft.Azure.Iot.Device --version 2.0.0-preview4
Replace Program.cs with:
using System.Security.Cryptography.X509Certificates;
using System.Text.Json;
using Microsoft.Azure.Iot.Device;
using Microsoft.Azure.Iot.Device.Authentication;
using Microsoft.Azure.Iot.Device.Models;
using Microsoft.Azure.Iot.Device.Models.Telemetry;
using Microsoft.Azure.Iot.Device.Unified.Connection;
using Microsoft.Azure.Iot.Device.Unified.Telemetry;
static string RequiredEnvironment(string name)
{
string? value = Environment.GetEnvironmentVariable(name);
return !string.IsNullOrWhiteSpace(value)
? value
: throw new InvalidOperationException($"Set {name} before running.");
}
using var certificate = X509CertificateLoader.LoadPkcs12FromFile(
RequiredEnvironment("DPS_DEVICE_PFX"),
RequiredEnvironment("DPS_DEVICE_PFX_PASSWORD"));
if (!certificate.HasPrivateKey)
{
throw new InvalidOperationException("The device certificate must include its private key.");
}
using var timeout = new CancellationTokenSource(TimeSpan.FromMinutes(2));
using var connection = new ConnectionClient();
var telemetry = new TelemetryClient(connection);
var authentication = new X509AuthenticationProvider(certificate, secondaryClientCertificate: null);
var provisioning = new ProvisioningSettings(RequiredEnvironment("DPS_ID_SCOPE"));
await connection.ProvisionAndConnectAsync(
provisioning, authentication, cancellationToken: timeout.Token);
string testId = Guid.NewGuid().ToString();
var message = new DeviceToCloudTelemetry
{
Payload = JsonSerializer.SerializeToUtf8Bytes(new
{
testId,
temperature = 21.5,
observedAt = DateTimeOffset.UtcNow
}),
ContentType = "application/json",
ContentEncoding = "utf-8",
MessageId = testId
};
await telemetry.SendTelemetryAsync(message, timeout.Token);
Console.WriteLine($"Publish completed for testId={testId}. Verify this ID at the destination.");
await connection.DisconnectAsync();
The SDK derives the provisioning registration identity from the certificate. Ensure it matches the enrollment. Let the platform validate the server certificate; don't disable validation to make a test connect.
Configure and run
Set DPS_ID_SCOPE and DPS_DEVICE_PFX in the current PowerShell session:
$env:DPS_ID_SCOPE = "<id-scope>"
$env:DPS_DEVICE_PFX = "<absolute-path-to-device.pfx>"
Supply DPS_DEVICE_PFX_PASSWORD through your local secret-handling mechanism
without recording it in a script or command history. Then run:
dotnet run
Inspect failures reported by the application instead of treating a timeout as successful publishing. After the test, remove credential environment variables from the session when no longer needed.
C
The C SDK is built from source. The following commands use release
2.0.0-preview.2, pinned to the c/2.0.0-preview.2 tag.
Install the toolchain, CMake, and OpenSSL prerequisites in the C samples guide. For Windows, use Developer PowerShell for Visual Studio 2022.
Get the sample
git clone --branch c/2.0.0-preview.2 --depth 1 https://github.com/Azure/azure-iot-sdk.git
Set-Location azure-iot-sdk
git submodule update --init --recursive
Set-Location c
Configure the device
$env:AZ_IOT_DPS_ID_SCOPE = "<id-scope>"
$env:AZ_IOT_DPS_REGISTRATION_ID = "<registration-id>"
$env:AZ_IOT_CLIENT_CERT = "<absolute-path-to-device-certificate-chain.pem>"
$env:AZ_IOT_CLIENT_KEY = "<absolute-path-to-device-private-key.pem>"
$env:AZ_IOT_TRUSTED_CA = "<absolute-path-to-trusted-server-ca-bundle.pem>"
The sample requires a registration ID that matches the device certificate's common name. The certificate chain file is in leaf-first order. The trusted CA bundle validates the DPS and IoT Hub servers. It isn't the device's private key or a replacement for the client certificate chain.
Build and run
cmake --preset windows-msvc-debug
cmake --build --preset windows-msvc-debug --target az_iot_sample_unified_telemetry
.\build\windows-msvc-debug\samples\unified\Debug\az_iot_sample_telemetry.exe
The unified telemetry sample sends JSON periodically for about a minute. Confirm that the DPS assignment uses MQTT v5. The sample can rebuild its telemetry client when the assigned profile differs from its initial assumption.
The C telemetry message accepts bytes and an explicit length. Its MQTT v5
telemetry helper defaults Content Type to application/json; don't reuse
that default for arbitrary binary. Content Type is overridden through
AZ_IOT_MSG_PROP_CONTENT_TYPE ($.ct).
Publish a custom-topic test message with .NET
After the standard telemetry test succeeds, continue with Publish a custom-topic test message with .NET. That example reuses this application's certificate loading and connection setup.
Verify the result
For either SDK:
- Confirm assignment to the intended hub.
- Inspect connection and publish outcomes.
- Read the configured destination during the test interval.
- For the .NET example, locate the printed
testId. For the C sample, identify the test device and JSON payload in that interval. - Compare the received data with the sent payload and inspect required metadata.
These SDK payload APIs don't require base64 conversion. Interpret the received payload according to the destination and its configured Message format. MQTT v5 hubs have no built-in telemetry endpoint or fallback route.
Verify actual delivery at the destination
A successful publish acknowledgment isn't proof of destination receipt. Follow Monitor a test run and Verify readiness with the receiving application to correlate the message with routing and destination evidence.
Verify the selective route
For the custom-topic example and its positive and negative routing checks, see Verify the selective route.
Troubleshoot provisioning and delivery
Before testing, configure diagnostic collection. Record the UTC interval, assigned device ID, and message identifier, but not credentials. To correlate provisioning, connection, ingress, routing, and destination receipt, follow Monitor a test run.
Use this checklist for MQTT v5-specific requirements:
| Symptom | MQTT v5-specific checks |
|---|---|
| Provisioning or authentication fails | Hub connections require X.509, not SAS. Symmetric-key onboarding requires configured DPS certificate issuance and a device certificate signing request; existing X.509 onboarding doesn't require new issuance. See Hub configuration troubleshooting and Troubleshoot a secure connection. |
| Custom-topic publish is refused | Check the configured templates, concrete publish topic, assigned hub device ID, and SDK acknowledgment. See Troubleshoot custom-topic publishing. |
| Publish succeeds but no data arrives | MQTT v5 hubs have no built-in telemetry endpoint or fallback route. Configure and enable an explicit route to a supported destination, then verify receipt there. |
For checks shared across connection profiles, use:
- Monitor a test run for provisioning, connection, ingress, routing, and consumption checkpoints.
- Troubleshoot message routing for routing metrics, resource logs, and endpoint health. Built-in-endpoint and fallback-route instructions apply only to the classic profile. For the custom-topic example's positive and negative checks, see Verify the selective route.
- Verify readiness with the receiving application for payload format, schema interpretation, and consumer field mapping.
- Message enrichments for enrichment keys, values, and target endpoints, and Fabric enrichment restrictions when using a Fabric destination.
Troubleshoot a secure connection
Use the assigned device endpoint, not a service endpoint. Check the device
clock, certificate and private key, server trust, and network access against
the shared TLS requirements.
If TLS succeeds but MQTT connection fails, inspect the MQTT v5 CONNACK
reason code and device registration. A successful TLS handshake doesn't prove
MQTT session establishment or application success.