DkmModule.GetRegisterRelativeSymbolName Method
Definition
Important
Some information relates to prerelease product that may be substantially modified before it’s released. Microsoft makes no warranties, express or implied, with respect to the information provided here.
Overloads
GetRegisterRelativeSymbolName(UInt32, Int32, UInt32, DkmProcessorArchitecture) |
Gets the symbol name for a register relative value. Location constraint: API must be called from an IDE component (component level > 100,000). This API was introduced in Visual Studio 16 RTM (DkmApiVersion.VS16RTM). |
GetRegisterRelativeSymbolName(DkmWorkList, UInt32, Int32, UInt32, DkmProcessorArchitecture, DkmCompletionRoutine<DkmGetRegisterRelativeSymbolNameAsyncResult>) |
Gets the symbol name for a register relative value. This method will append a new work item to the specified work list, and return once the work item has been appended. The actual processing of the work item is asynchronous. The caller will be notified that the request is complete through the completion routine. Location constraint: API must be called from an IDE component (component level > 100,000). This API was introduced in Visual Studio 16 RTM (DkmApiVersion.VS16RTM). |
GetRegisterRelativeSymbolName(UInt32, Int32, UInt32, DkmProcessorArchitecture)
Gets the symbol name for a register relative value.
Location constraint: API must be called from an IDE component (component level > 100,000).
This API was introduced in Visual Studio 16 RTM (DkmApiVersion.VS16RTM).
public:
System::String ^ GetRegisterRelativeSymbolName(System::UInt32 RVA, int RegIndex, System::UInt32 Offset, Microsoft::VisualStudio::Debugger::DkmProcessorArchitecture ProcessorArchitecture);
public string GetRegisterRelativeSymbolName (uint RVA, int RegIndex, uint Offset, Microsoft.VisualStudio.Debugger.DkmProcessorArchitecture ProcessorArchitecture);
public string? GetRegisterRelativeSymbolName (uint RVA, int RegIndex, uint Offset, Microsoft.VisualStudio.Debugger.DkmProcessorArchitecture ProcessorArchitecture);
member this.GetRegisterRelativeSymbolName : uint32 * int * uint32 * Microsoft.VisualStudio.Debugger.DkmProcessorArchitecture -> string
Public Function GetRegisterRelativeSymbolName (RVA As UInteger, RegIndex As Integer, Offset As UInteger, ProcessorArchitecture As DkmProcessorArchitecture) As String
Parameters
- RVA
- UInt32
[In] The RVA of the symbol.
- RegIndex
- Int32
[In] The register index.
- Offset
- UInt32
[In] The offset from the register.
- ProcessorArchitecture
- DkmProcessorArchitecture
[In] The processor architecture.
Returns
[Out,Optional] The symbol name for use in formatting.
Applies to
GetRegisterRelativeSymbolName(DkmWorkList, UInt32, Int32, UInt32, DkmProcessorArchitecture, DkmCompletionRoutine<DkmGetRegisterRelativeSymbolNameAsyncResult>)
Gets the symbol name for a register relative value.
This method will append a new work item to the specified work list, and return once the work item has been appended. The actual processing of the work item is asynchronous. The caller will be notified that the request is complete through the completion routine.
Location constraint: API must be called from an IDE component (component level > 100,000).
This API was introduced in Visual Studio 16 RTM (DkmApiVersion.VS16RTM).
public:
void GetRegisterRelativeSymbolName(Microsoft::VisualStudio::Debugger::DkmWorkList ^ WorkList, System::UInt32 RVA, int RegIndex, System::UInt32 Offset, Microsoft::VisualStudio::Debugger::DkmProcessorArchitecture ProcessorArchitecture, Microsoft::VisualStudio::Debugger::DkmCompletionRoutine<Microsoft::VisualStudio::Debugger::Symbols::DkmGetRegisterRelativeSymbolNameAsyncResult> ^ CompletionRoutine);
public void GetRegisterRelativeSymbolName (Microsoft.VisualStudio.Debugger.DkmWorkList WorkList, uint RVA, int RegIndex, uint Offset, Microsoft.VisualStudio.Debugger.DkmProcessorArchitecture ProcessorArchitecture, Microsoft.VisualStudio.Debugger.DkmCompletionRoutine<Microsoft.VisualStudio.Debugger.Symbols.DkmGetRegisterRelativeSymbolNameAsyncResult> CompletionRoutine);
member this.GetRegisterRelativeSymbolName : Microsoft.VisualStudio.Debugger.DkmWorkList * uint32 * int * uint32 * Microsoft.VisualStudio.Debugger.DkmProcessorArchitecture * Microsoft.VisualStudio.Debugger.DkmCompletionRoutine<Microsoft.VisualStudio.Debugger.Symbols.DkmGetRegisterRelativeSymbolNameAsyncResult> -> unit
Public Sub GetRegisterRelativeSymbolName (WorkList As DkmWorkList, RVA As UInteger, RegIndex As Integer, Offset As UInteger, ProcessorArchitecture As DkmProcessorArchitecture, CompletionRoutine As DkmCompletionRoutine(Of DkmGetRegisterRelativeSymbolNameAsyncResult))
Parameters
- WorkList
- DkmWorkList
WorkList to append the new work item to.
- RVA
- UInt32
[In] The RVA of the symbol.
- RegIndex
- Int32
[In] The register index.
- Offset
- UInt32
[In] The offset from the register.
- ProcessorArchitecture
- DkmProcessorArchitecture
[In] The processor architecture.
- CompletionRoutine
- DkmCompletionRoutine<DkmGetRegisterRelativeSymbolNameAsyncResult>
Routine to fire when the request is complete. If the request is successfully appended to the work list, this will always fire (including when the operation is canceled). This will never fire if appending the work item fails.