Note
Access to this page requires authorization. You can try signing in or changing directories.
Access to this page requires authorization. You can try changing directories.
The SMS_MeterData
Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that represents captured software metering data.
The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.
Syntax
Class SMS_MeterData : SMS_BaseClass
{
Boolean EndNotCaptured;
DateTime EndTime;
UInt32 EndTimeOffset;
SInt64 FileID;
Boolean InTSSession;
String MeterDataID;
UInt32 MeteredUserID;
Boolean Released;
UInt32 ResourceID;
Boolean Started;
Boolean StartNotCaptured;
DateTime StartTime;
UInt32 StartTimeOffset;
Boolean StillRunning;
UInt32 TimeSerial;
};
Methods
The SMS_MeterData
class does not define any methods.
Properties
EndNotCaptured
Data type: Boolean
Access type: Read/Write
Qualifiers: None
true
if the metering agent could not capture the actual end time of the process.
EndTime
Data type: DateTime
Access type: Read/Write
Qualifiers: [key]
The date and time, in Universal Coordinated Time (UTC), when the process stopped running, if StillRunning
is false
. If it is true
, EndTime
represents the time at which the data was reported.
EndTimeOffset
Data type: UInt32
Access type: Read/Write
Qualifiers: None
The offset from UTC, in minutes, of the local time for the client at the time the data was reported.
FileID
Data type: SInt64
Access type: Read/Write
Qualifiers: None
ID of the file that was metered. To find the file information, match FileID
with the ID in SMS_ProductFileInfo Server WMI Class. To find the rules that caused the file to be metered, match FileID
with the ID in SMS_MeteredFiles Server WMI Class.
InTSSession
Data type: Boolean
Access type: Read/Write
Qualifiers: None
true
if the file was used in a Terminal Server session. Set the property to false
if the file was used in a console session.
MeterDataID
Data type: String
Access type: Read/Write
Qualifiers: [key]
Unique ID of a particular instance of a running process on a particular computer. A record with this ID is created every time the client reports on the same instance of a running program.
MeteredUserID
Data type: UInt32
Access type: Read/Write
Qualifiers: None
ID of the Windows user account of the programs user. To find the user name, the application finds the record with the same MeteredUserID
property in the SMS_MeteredUser Server WMI Class class.
Released
Data type: Boolean
Access type: Read/Write
Qualifiers: None
Internal flag used by the metering system and signifying that the record can be deleted by the Delete Aged Software Metering Data site maintenance task.
ResourceID
Data type: UInt32
Access type: Read/Write
Qualifiers: None
ID of the computer that executed the metered program. To find the computer information, your application finds the record with the same resource ID in the SMS_R_System Server WMI Class class.
Started
Data type: Boolean
Access type: Read/Write
Qualifiers: None
true
if this is the first record reporting on a particular instance of a running program. If this property is set to true
, StartTime
represents the actual time when the program started.
StartNotCaptured
Data type: Boolean
Access type: Read/Write
Qualifiers: None
true
if the metering agent was not able to capture the actual start time of the process.
StartTime
Data type: DateTime
Access type: Read/Write
Qualifiers: None
The date and time, in Universal Coordinated Time (UTC), when the program started, if Started
is true
. If it is false
, StartTime
is the end time (EndTime
) of the previous report for this program.
StartTimeOffset
Data type: UInt32
Access type: Read/Write
Qualifiers: None
The offset from UTC, in minutes, of the local time for the client at the time the data was reported.
StillRunning
Data type: Boolean
Access type: Read/Write
Qualifiers: None
true
if the program is still running. Set this property to false
if EndTime
represents the actual end time of the metered program.
TimeSerial
Data type: UInt32
Access type: Read/Write
Qualifiers: None
A rough ordering of the time used to process the record. Records with a smaller TimeSerial
value were processed before a record with a larger TimeSerial
value. This property is not unique across records.
Remarks
There are no special class qualifiers for this class. For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager Class and Property Qualifiers.
Each record represents a report of a running program on a computer. If a program runs over several reporting cycles, there are several instances of SMS_MeterData
that report on it, all with the same MeterDataID
value. The time periods specified by StartTime
and EndTime
are consecutive and do not overlap. The full period of program execution can be found by the earliest StartTime
value (where Started
= 1) and the latest EndTime
value (where StillRunning
= 0).
Requirements
Runtime Requirements
For more information, see Configuration Manager Server Runtime Requirements.