Edit

SMS_CH_Settings Server WMI Class

The SMS_CH_Settings Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that represents client status settings.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.

Syntax

Class SMS_CH_Settings : SMS_BaseClass
{
    String ADRetrievingSchedule;
    UInt32 CleanUpInterval;
    UInt32 DDRInactiveInterval;
    UInt32 HWInactiveInterval;
    Boolean NeedADLastLogonTime;
    UInt32 PolicyInactiveInterval;
    UInt32 SettingsID;
    UInt32 StatusInactiveInterval;
    UInt32 SWInactiveInterval;
};

Methods

The SMS_CH_Settings class does not define any methods.

Properties

ADRetrievingSchedule Data type: String

Access type: Read/Write

Qualifiers: none

Schedule for how frequently the system retrieves information from Active Directory.

CleanUpInterval Data type: UInt32

Access type: Read/Write

Qualifiers: none

History clean up interval.

DDRInactiveInterval Data type: UInt32

Access type: Read/Write

Qualifiers: none

Heartbeat discovery inactive interval.

HWInactiveInterval Data type: UInt32

Access type: Read/Write

Qualifiers: none

Hardware inventory inactive interval.

NeedADLastLogonTime Data type: Boolean

Access type: Read/Write

Qualifiers: none

Last logged on time from Active Directory.

PolicyInactiveInterval Data type: UInt32

Access type: Read/Write

Qualifiers: none

Policy request inactive interval.

SettingsID Data type: UInt32

Access type: Read/Write

Qualifiers: [key]

Settings ID.

StatusInactiveInterval Data type: UInt32

Access type: Read/Write

Qualifiers: none

Status message inactive interval.

SWInactiveInterval Data type: UInt32

Access type: Read/Write

Qualifiers: none

Software inventory inactive interval.

Requirements

Runtime Requirements

For more information, see Configuration Manager Server Runtime Requirements.

Development Requirements

For more information, see Configuration Manager Server Development Requirements.