2.3.3.1.18 VtHyperlink
Referenced by: VecVtHyperlink
Specifies the data format for a hyperlink for a property.
|
|
|
|
|
|
|
|
|
|
1 |
|
|
|
|
|
|
|
|
|
2 |
|
|
|
|
|
|
|
|
|
3 |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
dwHash |
|||||||||||||||||||||||||||||||
... |
|||||||||||||||||||||||||||||||
dwApp |
|||||||||||||||||||||||||||||||
... |
|||||||||||||||||||||||||||||||
dwOfficeArt |
|||||||||||||||||||||||||||||||
... |
|||||||||||||||||||||||||||||||
dwInfo |
|||||||||||||||||||||||||||||||
... |
|||||||||||||||||||||||||||||||
hlink1 (variable) |
|||||||||||||||||||||||||||||||
... |
|||||||||||||||||||||||||||||||
hlink2 (variable) |
|||||||||||||||||||||||||||||||
... |
dwHash (8 bytes): MUST be a VT_I4 TypedPropertyValue as specified in [MS-OLEPS] section 2.15. The Value field of this structure SHOULD be calculated as specified in the Hyperlink Hash (section 2.4.2) section with the hlink1 field and hlink2 field string values given as input.<21>
dwApp (8 bytes): MUST be a VT_I4 TypedPropertyValue as specified in [MS-OLEPS] section 2.15. The Value field of this structure is implementation specific.<22>
dwOfficeArt (8 bytes): MUST be a VT_I4 TypedPropertyValue as specified in [MS-OLEPS] section 2.15. The Value field of this structure MUST be a MSOSPID type value ([MS-ODRAW] section 2.1.2) specifying the identifier of the shape ([MS-ODRAW] section 2.2.31) to which this hyperlink applies in the document. If this hyperlink does not apply to a shape, the Value field of this structure MUST be 0x00000000.
dwInfo (8 bytes): MUST be a VT_I4 TypedPropertyValue as specified in [MS-OLEPS] section 2.15. The Value field of this structure is implementation specific.<23> The high-order 2-byte integer of the Value field of this structure SHOULD be 0x0000. The unsigned 2-byte integer specified by the high two bytes of this value can be written as 0x0000 by an application that saves the entire file, as it specifies that the hyperlink is in sync with the document contents. If a process changes the hyperlink property element without a corresponding change to the related document content such that the hyperlink needs to be fixed in the document the next time the document is loaded, this value needs to be changed to 0x0001 by the process. If such a process wishes to specify that the hyperlink is to be removed from the document the next time the document is loaded, this value needs to be changed to 0x0002 by the process.
hlink1 (variable): MUST be a VtString structure (section 2.3.3.1.11) with hlink1.wType equal to VT_LPWSTR. hlink1.stringValue specifies the hyperlink target.
hlink2 (variable): MUST be a VtString structure (section 2.3.3.1.11) with hlink2.wType equal to VT_LPWSTR. hlink2.stringValue specifies the hyperlink location.