2.4.62 ContinueFrt12

The ContinueFrt12 record specifies a continuation of the data in a preceding Future Record Type record that has data longer than 8,224 bytes. Such records are split into several records. The first section of the data appears in the base record and subsequent sections appear in one or more ContinueFrt12 records that appear after the base record. The preceding base record MUST contain a FrtRefHeader or a FrtHeader field.


0


1


2


3


4


5


6


7


8


9

1
0


1


2


3


4


5


6


7


8


9

2
0


1


2


3


4


5


6


7


8


9

3
0


1

frtRefHeader

...

...

rgb (variable)

...

frtRefHeader (12 bytes):  An FrtRefHeader structure. The frtRefHeader.rt field MUST be 0x087F. If frtRefHeader.grbitFrt.fFrtRef is 1 then the frtRefHeader.ref8 MUST refer to the range of cells associated with this record. If frtRefHeader.grbitFrt.fFrtRef is 0 then all of the fields of the frtRefHeader.ref8 structure MUST be zero and MUST be ignored.

rgb (variable):  A binary stream that specifies the record data. The number of bytes in this stream MUST be less than 8,213.