3.17.4.1.54 ConnectorTypeGuid (Opnum 60)
The ConnectorTypeGuid method is received by the server in an RPC_REQUEST packet. In response, the server MUST set the represented Message.ConnectorTypeIdentifier.
-
[propput] HRESULT ConnectorTypeGuid( [in] BSTR bstrGuidConnectorType );
bstrGuidConnectorType: A pointer to a BSTR that contains the GUID that will be stored with the message. The string MUST adhere to the following format, specified using ABNF.
-
guid = "{" dword-part "-" word-part "-" word-part "-" 2byte-part "-" 6byte-part "}" dword-part = 2word-part word-part = 2byte-part byte-part = 2hex-digit hex-digit = %x30-39 / %x41-46 / %x61-66
Return Values: The method MUST return S_OK (0x00000000) on success or an implementation-specific error HRESULT on failure.
When processing this call, the server MUST follow these guidelines:
If the bstrGuidConnectorType input parameter is NOT compliant with the format previously specified:
Return MQ_ERROR_ILLEGAL_PROPERTY_VALUE (0xC00E0018), and take no further action.
Set the represented Message.ConnectorTypeIdentifier to the value contained in the bstrGuidConnectorType input parameter.