3.1.4.2.89 ApiNetworkControl (Opnum 89)
(Protocol Version 3) The ApiNetworkControl method instructs the server to initiate, on the specified cluster network, an operation that is defined by the specified control code. The operation is executed on the node where the specified cluster network context handle was obtained.
The server MUST require that the access level associated with the hNetwork context handle is "All" (section 3.1.4), if and only if the bitwise AND of dwControlCode and 0x00400000 is not equal to zero.
-
error_status_t ApiNetworkControl( [in] HNETWORK_RPC hNetwork, [in] DWORD dwControlCode, [in, unique, size_is(nInBufferSize)] UCHAR *lpInBuffer, [in] DWORD nInBufferSize, [out, size_is(nOutBufferSize), length_is (*lpBytesReturned)] UCHAR *lpOutBuffer, [in] DWORD nOutBufferSize, [out] DWORD *lpBytesReturned, [out] DWORD *lpcbRequired, [out] error_status_t *rpc_status );
hNetwork: An HNETWORK_RPC context handle that is obtained in a previous ApiOpenNetwork or ApiOpenNetworkEx method call.
dwControlCode: Indicates the operation to perform on the cluster network. MUST be one of the following values.
-
Value
Meaning
0x5000000
Verifies that control codes for the cluster network are being processed.
CLUSCTL_NETWORK_GET_CHARACTERISTICS
0x5000005
Retrieves the intrinsic characteristics associated with the cluster network.
0x5000009
Retrieves the flags that are set for the cluster network.
0x5000029
Retrieves the name of the cluster network.
0x5000039
Retrieves the unique ID for the cluster network.
CLUSCTL_NETWORK_ENUM_COMMON_PROPERTIES
0x5000051
Retrieves a list of the common property names for the designated cluster network.
CLUSCTL_NETWORK_GET_RO_COMMON_PROPERTIES
0x5000055
Retrieves the read-only common property values for the designated cluster network.
CLUSCTL_NETWORK_GET_COMMON_PROPERTIES
0x5000059
Retrieves all common property values for the designated cluster network.
CLUSCTL_NETWORK_SET_COMMON_PROPERTIES
0x540005E
Sets the common property values for the designated cluster network.
CLUSCTL_NETWORK_VALIDATE_COMMON_PROPERTIES
0x5000061
Validates that the values supplied for the common properties are acceptable for the designated cluster network.
CLUSCTL_NETWORK_ENUM_PRIVATE_PROPERTIES
0x5000079
Retrieves a list of the private property names for the designated cluster network.
CLUSCTL_NETWORK_GET_RO_PRIVATE_PROPERTIES
0x500007D
Retrieves the read-only private property names for the designated cluster network.
CLUSCTL_NETWORK_GET_PRIVATE_PROPERTIES
0x5000081
Retrieves all private property values for the designated cluster network.
CLUSCTL_NETWORK_SET_PRIVATE_PROPERTIES
0x5400086
Sets the private property values for the designated cluster network.
CLUSCTL_NETWORK_VALIDATE_PRIVATE_PROPERTIES
0x5000089
Validates that the supplied property list is valid.
lpInBuffer: The input data for the operation that is specified by dwControlCode. See the following sections for the data structures that are required for each dwControlCode.
nInBufferSize: The size, in bytes, of the buffer that is specified by lpInBuffer.
lpOutBuffer: The output data for the operation that is specified by dwControlCode. The output buffer MUST be allocated and provided by the client.
nOutBufferSize: The available size of the buffer that is specified by lpOutBuffer, as allocated by the client.
lpBytesReturned: On successful completion of the method, the server MUST set lpBytesReturned to the number of bytes that are written to the lpOutBuffer buffer.
lpcbRequired: If nOutBufferSize indicates that the buffer that is specified by lpOutBuffer is too small for the output data, the server MUST return 0x000000EA (ERROR_MORE_DATA) and set lpcbRequired to the number of bytes that are required for the output buffer. If the method completes successfully and lpBytesReturned is 0x00000000 then the server MUST set lpcbRequired to 0x00000000. In any other condition the client MUST ignore lpcbRequired after this method completes.
rpc_status: A 32-bit integer used to indicate success or failure. The RPC runtime MUST indicate, by writing to this parameter, whether it succeeded in executing this method on the server. The encoding of the value passed in this parameter MUST conform to encoding for comm_status and fault_status, as specified in Appendix E of [C706].
Return Values: The method MUST return the following error codes for the specified conditions.
-
Return value/code
Description
0x00000000
ERROR_SUCCESS
Success.
0x00000001
ERROR_INVALID_FUNCTION
The cluster network that is designated by hNetwork does not support the operation that is designated by dwControlCode.
0x0000000D
ERROR_INVALID_DATA
The input data was invalid or was incorrectly formatted.
0x00000057
ERROR_INVALID_PARAMETER
The input data was invalid or was incorrectly formatted.
0x000000EA
ERROR_MORE_DATA
The nOutBufferSize parameter indicates that the buffer that is pointed to by lpOutBuffer is not large enough to hold the data that resulted from the operation.
For any other conditions, this method MUST return a value that is not one of the values listed in the preceding table. The client MUST behave in one consistent, identical manner for all values that are not listed in the preceding table. The client SHOULD treat errors specified in section 3.2.4.6 as recoverable errors and initiate the reconnect procedure as specified in section 3.2.4.6.
Upon receiving this message, the server MUST:
Determine the number of bytes that are required for lpOutBuffer. If the size indicated by nOutBufferSize is less than the number of bytes that are required for lpOutBuffer, return ERROR_MORE_DATA (0x000000EA), except as specified in the following sub-sections where a different value is returned, and set lpcbRequired to the number of bytes that are required for the output buffer.
Return either ERROR_INVALID_DATA or ERROR_INVALID_PARAMETER if the input data is invalid or incorrectly formatted. The client MUST treat these two error codes the same.