Start-HcsHotfix
Installs a hotfix on a StorSimple device.
Syntax
Start-HcsHotfix
[-Force]
[-Credential <PSCredential>]
-Path <String>
[-WhatIf]
[-Confirm]
[<CommonParameters>]
Description
The Start-HcsHotfix cmdlet installs a hotfix on a StorSimple device. You must install maintenance mode updates on each controller individually. If you do not install a maintenance mode hotfix on each controller, data may become lost or corrupted.
Examples
Example 1: Install a hotfix
PS C:\>Start-HcsHotfix -Path "\\myshare\hotfix\hotfix.exe"
This command installs a hotfix on a StorSimple device.
Parameters
-Confirm
Prompts you for confirmation before running the cmdlet.
Type: | SwitchParameter |
Aliases: | cf |
Position: | Named |
Default value: | False |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-Credential
Specifies a PSCredential object.
Specify a credential that has read permission for the location that the Path parameter specifies.
To obtain a PSCredential object, use the Get-Credentialhttp://go.microsoft.com/fwlink/?LinkID=293936 cmdlet.
For more information, type Get-Help Get-Credential
.
Type: | PSCredential |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-Force
Forces the command to run without asking for user confirmation.
Type: | SwitchParameter |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-Path
Specifies a file name, including the path, to the hotfix to install. The hotfix must be on a share that the StorSimple device has access to. If the share requires credentials, they must be supplied with the Credential parameter.
If you have trouble accessing a network share by specifying a name (for example, \\mysharehost\temp\), try accessing it by IP address instead (for example, \\192.168.0.25\temp\). Because this device is not joined to a domain, accessing network shares by name does not always work, depending on the configuration of your network. The device cannot communicate over IPSEC enabled networks.
Type: | String |
Position: | Named |
Default value: | None |
Required: | True |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-WhatIf
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Type: | SwitchParameter |
Aliases: | wi |
Position: | Named |
Default value: | False |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |