Set-EntraApplicationProxyApplication

The Set-EntraApplicationProxyApplication allows you to modify and set configurations for an application in Microsoft Entra ID configured to use ApplicationProxy.

Syntax

Set-EntraApplicationProxyApplication
   -ObjectId <String>
   [-ExternalUrl <String>]
   [-InternalUrl <String>]
   [-ExternalAuthenticationType <ExternalAuthenticationTypeEnum>]
   [-IsTranslateHostHeaderEnabled <Boolean>]
   [-IsHttpOnlyCookieEnabled <Boolean>]
   [-IsSecureCookieEnabled <Boolean>]
   [-IsPersistentCookieEnabled <Boolean>]
   [-IsTranslateLinksInBodyEnabled <Boolean>]
   [-ApplicationServerTimeout <ApplicationServerTimeoutEnum>]
   [-ConnectorGroupId <String>]
   [<CommonParameters>]

Description

The Set-EntraApplicationProxyApplication allows you to modify and set more settings for an application in Microsoft Entra ID configured to use ApplicationProxy.

Examples

PS C:\> Set-EntraApplicationProxyApplication -ObjectId 257098d1-f8dd-4efb-88a2-1c92d3654f10 -IsTranslateLinksInBodyEnabled $true

ExternalAuthenticationType               : AadPreAuthentication
ApplicationServerTimeout                 : Default
ExternalUrl                              : https://finance-awcycles.msappproxy.net/
InternalUrl                              : https://finance/
IsTranslateHostHeaderEnabled             : True
IsTranslateLinksInBodyEnabled            : True
IsOnPremPublishingEnabled                : True
VerifiedCustomDomainCertificatesMetadata : 
VerifiedCustomDomainKeyCredential        : 
VerifiedCustomDomainPasswordCredential   : 
SingleSignOnSettings                     :

This command adds the link translation feature to an application.

Parameters

-ApplicationServerTimeout

Specifies the backend server timeout type. Set this value to Long only if your application is slow to authenticate and connect.

Type:ApplicationServerTimeoutEnum
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-ConnectorGroupId

Provide the ID of the Connector group you would like assigned to this application. You can find this value by using the Get-EntraApplicationProxyConnectorGroup command. Connectors process the remote access to your application, and connector groups help you organize connectors and apps by region, network, or purpose. If you don't have any connector groups created yet, your app is assigned to Default.

Type:String
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-ExternalAuthenticationType

How Application Proxy verifies users before giving them access to your application. AadPreAuthentication: Application Proxy redirects users to sign in with Microsoft Entra ID, which authenticates their permissions for the directory and application. We recommend keeping this option as the default, so that you can take advantage of Microsoft Entra ID security features like conditional access and multifactor authentication. Pass through: Users don't have to authenticate against Microsoft Entra ID to access the application. You can still set up authentication requirements on the backend.

Type:ExternalAuthenticationTypeEnum
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-ExternalUrl

The address your users go to in order to access the app from outside your network.

Type:String
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-InternalUrl

The URL that you use to access the application from inside your private network. You can provide a specific path on the backend server to publish, while the rest of the server is unpublished. In this way, you can publish different sites on the same server as different apps, and give each one its own name and access rules. If you publish a path, make sure that it includes all the necessary images, scripts, and style sheets for your application.

Type:String
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-IsHttpOnlyCookieEnabled

Allows application proxy to include the HTTPOnly flag in HTTP response headers. This flag provides extra security benefits, for example, it prevents client-side scripting (CSS) from copying or modifying the cookies.

Type:Boolean
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-IsPersistentCookieEnabled

Allows application proxy to set its access cookies to not expire when the web browser is closed. The persistence lasts until the access token expires, or until the user manually deletes the persistent cookies.

Type:Boolean
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-IsSecureCookieEnabled

Allows application proxy to include the Secure flag in HTTP response headers. Secure Cookies enhances security by transmitting cookies over a TLS secured channel such as HTTPS. TLS prevents cookie transmission in clear text.

Type:Boolean
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-IsTranslateHostHeaderEnabled

If set to true, translates urls in headers. Keep this value true unless your application required the original host header in the authentication request.

Type:Boolean
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-IsTranslateLinksInBodyEnabled

If set to true, translates urls in body. Keep this value as No unless your hardcoded HTML links to other on-premises applications, and don't use custom domains.

Type:Boolean
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-ObjectId

Specifies a unique application ID of an application in Microsoft Entra ID. This can be found using the Get-EntraApplication command.

Type:String
Position:Named
Default value:None
Required:True
Accept pipeline input:True
Accept wildcard characters:False

Notes