This command uses the Get-StorageSubSystem cmdlet to get the specified StorageSubsystem object, and uses the pipeline operator to pass it to Get-StorageHealthReport to display its health report.
Parameters
-AsJob
Runs the cmdlet as a background job. Use this parameter to run commands that take a long time to complete.
Parameter properties
Type:
SwitchParameter
Default value:
None
Supports wildcards:
False
DontShow:
False
Parameter sets
(All)
Position:
Named
Mandatory:
False
Value from pipeline:
False
Value from pipeline by property name:
False
Value from remaining arguments:
False
-CimSession
Runs the cmdlet in a remote session or on a remote computer.
Enter a computer name or a session object, such as the output of a New-CimSession or Get-CimSession cmdlet.
The default is the current session on the local computer.
Parameter properties
Type:
CimSession
Default value:
None
Supports wildcards:
False
DontShow:
False
Parameter sets
(All)
Position:
Named
Mandatory:
False
Value from pipeline:
False
Value from pipeline by property name:
False
Value from remaining arguments:
False
-Count
Specifies the number of report objects to be collected when the report runs.
The default value is one (1).
The maximum value is 300.
Parameter properties
Type:
Int32
Default value:
None
Supports wildcards:
False
DontShow:
False
Parameter sets
(All)
Position:
Named
Mandatory:
False
Value from pipeline:
False
Value from pipeline by property name:
False
Value from remaining arguments:
False
-InputObject
Specifies the input object that is used in a pipeline command.
Parameter properties
Type:
CimInstance
Default value:
None
Supports wildcards:
False
DontShow:
False
Parameter sets
(All)
Position:
Named
Mandatory:
True
Value from pipeline:
True
Value from pipeline by property name:
False
Value from remaining arguments:
False
-ThrottleLimit
Specifies the maximum number of concurrent operations that can be established to run the cmdlet.
If this parameter is omitted or a value of 0 is entered, then Windows PowerShell® calculates an optimum throttle limit for the cmdlet based on the number of CIM cmdlets that are running on the computer.
The throttle limit applies only to the current cmdlet, not to the session or to the computer.
Parameter properties
Type:
Int32
Default value:
None
Supports wildcards:
False
DontShow:
False
Parameter sets
(All)
Position:
Named
Mandatory:
False
Value from pipeline:
False
Value from pipeline by property name:
False
Value from remaining arguments:
False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable,
-InformationAction, -InformationVariable, -OutBuffer, -OutVariable, -PipelineVariable,
-ProgressAction, -Verbose, -WarningAction, and -WarningVariable. For more information, see
about_CommonParameters.