Add Method of the IFPCScheduledContentDownload Interface
The Add method creates a new FPCScheduledContentDownloadConfig object in the collection and returns a reference to it.
C++
Syntax
HRESULT Add(
[in] BSTR Name,
[in] BSTR URL,
[out] IFPCScheduledContentDownloadConfig** ppNewScheduledContentDownloadConfig
);
Parameters
Name
Required. BSTR that specifies the name of the content download job.URL
Required. BSTR that specifies the URL from which content is to be fetched.ppNewScheduledContentDownloadConfig
Address of an interface pointer that on return points to the new IFPCScheduledContentDownloadConfig interface created.
Return Value
This method can return one of the following:
- S_OK, indicating that the operation succeeded.
- An error code, indicating that the operation failed. In this case, the [out] parameter returned is a null object.
Visual Basic
Syntax
Function Add( _
ByVal Name As String, _
ByVal URL As String _
) As FPCScheduledContentDownloadConfig
Parameters
- Name
Required. String that specifies the name of the new content download job. - URL
Required. String that specifies the URL from which content is to be fetched.
Return Value
This method returns a reference to an FPCScheduledContentDownloadConfig object if successful. Otherwise, an error is raised that can be intercepted by using an error handler.
Remarks
The content download job created can run only if:
- The Local Host network is configured to listen for requests from Web proxy clients (see the EnableWebProxyClients property of the FPCNetwork object representing the Local Host network).
- There is a Web listener (an FPCWebListener object) that listens for requests from the Local Host network.
- The Scheduled Download Jobs system policy configuration group is enabled (see the Enabled property of the FPCSystemPolicyConfigGroup object), or an access rule that allows HTTP traffic to the All Networks network set from the Local Host network is enabled.
- The Microsoft Firewall service and the Microsoft Forefront TMG Job Scheduler service are running (see the FirewallServiceStatus and JobSchedulerServiceStatus properties of the applicable FPCServer object).
- The Web proxy is enabled (see the Enabled property of the FPCApplicationFilter object representing the Web Proxy Filter add-in).
In addition, downloaded content can be stored in the Forefront TMG cache only if a cache drive with a size (CacheLimitInMegs) greater than zero is configured.
Requirements
Client | Requires Windows 7 or Windows Vista. |
Server | Requires Windows Server 2008 R2 or Windows Server 2008 x64 Edition with SP2. |
Version | Requires Forefront Threat Management Gateway (TMG) 2010. |
IDL | Declared in Msfpccom.idl. |
DLL | Requires Msfpccom.dll. |
See Also
Send comments about this topic to Microsoft
Build date: 6/30/2010