Share via


IWMSBasicPlugin::InitializePlugin

banner art

Previous Next

IWMSBasicPlugin::InitializePlugin

The server calls the InitializePlugin method to initialize a plug-in.

Syntax

  HRESULT InitializePlugin(
  IWMSContext*  pServerContext,
  IWMSNamedValues*  pNamedValues,
  IWMSClassObject*  pClassFactory
  );

Parameters

pServerContext

[in] Pointer to an IWMSContext interface containing the server context.

pNamedValues

[in] Pointer to an IWMSNamedValues interface containing a collection of properties for the plug-in. The properties can be specified initially during the registration process. For more information, see Registering Plug-in Properties. The properties appear in the server namespace and can be edited by using the IWMSNamedValue interface.

pClassFactory

[in] Pointer to an IWMSClassObject interface that the plug-in can use to create IWMSContext, IWMSCommandContext, IWMSPacket, and IWMSPacketList objects.

Return Values

If the method succeeds, the plug-in must return S_OK. To report an error, the plug-in can return any HRESULT other than S_OK. If the plug-in uses the IWMSEventLog interface to log error information directly to the Windows Event Viewer, it is recommended that it return NS_E_PLUGIN_ERROR_REPORTED. Typically, the server attempts to make plug-in error information available to the server object model, the Windows Event Viewer, and the troubleshooting list in the details pane of the Windows Media Services MMC. However, if the plug-in uses the IWMSEventLog interface to send custom error information to the Windows Event Viewer, returning NS_E_PLUGIN_ERROR_REPORTED stops the server from also logging to the event viewer. For more information about retrieving plug-in error information, see Identifying Plug-in Errors.

Remarks

The InitializePlugin method is implemented by the plug-in and called by the server. The server calls the method only when the plug-in is created. The minimum implementation is S_OK. The InitializePlugin and IWMSBasicPlugin::EnablePlugin methods must return S_OK before the server can successfully enable and use the plug-in. InitializePlugin is called before EnablePlugin.

Example Code

STDMETHODIMP CPlugin::InitializePlugin
(
    IWMSContext *pServerContext, 
    IWMSNamedValues *pNamedValues,
    IWMSClassObject *pClassFactory
)
{
    HRESULT hr = S_OK;

    // Check for NULL pointers.
    if ( ( NULL == pServerContext )
        || ( NULL == pNamedValues )
        || ( NULL == pClassFactory ) )
    {
        return( E_INVALIDARG );
    }

    // Retrieve a pointer to the IWMSServer interface from the 
    // server context.
    hr = pServerContext->GetAndQueryIUnknownValue( 
                                     const_cast<LPWSTR>( WMS_SERVER ), 
                                     WMS_SERVER_ID,
                                     IID_IWMSServer,
                                     (IUnknown**) &m_pServer,
                                     0 );

    if( SUCCEEDED( hr ) )
    {
         // TODO: Continue initializing the plug-in.
    }

    return( hr );
}

Requirements

Header: wmsbasicplugin.h.

Library: WMSServerTypeLib.dll.

Platform: Windows Server 2003, Enterprise Edition; Windows Server 2003, Datacenter Edition; Windows Server 2008.

See Also

Previous Next