MSFT_SIPDataMCUProxyServerData
This content is no longer actively maintained. It is provided as is, for anyone who may still be using these technologies, with no warranties or claims of accuracy with regard to the most recent product version or service release.
Specifies the Web Conferencing Edge Server FQDNs including the internal FQDN to which the internal Web Conferencing Server connects and the External FQDN to which external users connect for Web Conferencing functionality.
MSFT_SIPDataMCUProxyServerData
The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties. Properties are listed in alphabetic order, not MOF order.
Syntax
class MSFT_SIPDataMCUProxyServerData
{
[key] string Backend;
string ExternalFQDN;
[key] string InstanceID;
string InternalFQDN;
};
Methods
This class does not define any methods.
Properties
The MSFT_SIPDataMCUProxyServerData class has the following properties.
Backend
Data type: [key] stringAccess type: Read-only
Required: When accessing data from any role that belongs to a pool. This property must be empty when accessing data from the Edge Server or Proxy Server role.
This property identifies the instance of SQL Server that manages the back-end database for Office Communications Server.
The value for this property depends on the topology of Office Communications Server.
Topology
Value
Standard Edition
(local)\rtc
Enterprise Edition
(consolidated or expanded configuration)
computername\instancename
or
computername
For Enterprise Edition, computername identifies either the FQDN or the NetBIOS name of the host computer for SQL Server and instancename identifies a named instance of SQL Server on the host computer. The value computername by itself specifies the default instance of SQL Server on the host computer.
ExternalFQDN
Data type: stringAccess type: Read/Write
Required. Specifies the fully qualified domain name (FQDN) of the external edge of the Web Conferencing Edge Server.
External users connect to their FQDN for Web Conferencing functionality.
The value must be an FQDN. An IP address is not allowed.
InstanceID
Data type: [key] stringAccess type: Read-only
Optional. A GUID value that uniquely identifies an instance of this class.
The GUID must be encapsulated between the "{" and "}" braces; for example: "{01234567-0123-4567-89AB-CDEF01234567}".
InternalFQDN
Data type: stringAccess type: Read/Write
Required. Specifies the FQDN of the internal edge of the Web Conferencing Edge Server.
The internal Web Conferencing Server connects to this FQDN to provide Web Conferencing functionality to external users.
The value must be an FQDN. An IP address is not allowed.
Remarks
This class gets and sets information at the following levels: SQL.
Instances of this class support the following interface methods:
Provider::DeleteInstance();
Provider::EnumerateInstances();
Provider::GetObject();
Provider::PutInstance();
Where PutInstance() supports the following flags:
WBEM_FLAG_CREATE_ONLY
WBEM_FLAG_UPDATE_ONLY
WBEM_FLAG_CREATE_OR_UPDATE
Requirements
Server: Installed on computers serving the following roles: Administrative Tools Server and Web Conferencing Server.
Namespace: Defined in \root\cimv2.