MSFT_SIPQMSSingleMaskSubnet (New)
This content is no longer actively maintained. It is provided as is, for anyone who may still be using these technologies, with no warranties or claims of accuracy with regard to the most recent product version or service release.
This class contains defines network grouping settings for monitoring and reporting.
The properties in the MSFT_SIPQMSSingleMaskSubnet class do not map directly to the Office Communications Server 2007 R2 Administration Tool.
MSFT_SIPQMSSingleMaskSubnet
Properties for this class are populated by the monitoring database during an insert.
The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties. Properties are listed in alphabetic order, not MOF order.
Syntax
class MSFT_SIPQMSSingleMaskSubnet
{
[key] string Backend;
[key] string InstanceID;
boolean Monitored;
sint32 NextUpdateTS;
sint32 Subnet;
};
Methods
This class does not define any methods.
Properties
The MSFT_SIPQMSSingleMaskSubnet class has the following properties.
Backend
Data type: [key] stringAccess type: Read-only
Required: Identifies the instance of SQL Server that manages the database for Monitoring Server.
This property specifies the database server using the following format:
computername\instancename
The value computername identifies either the FQDN or the NetBIOS name of the host computer for SQL Server and instancename identifies a named instance of SQL Server on the host computer.
The maximum length of the string is 273 characters.
InstanceID
Data type: [key] stringAccess type: Read-only
Required.
A GUID value that uniquely identifies an instance of this class. The GUID must be encapsulated between the "{" and "}" braces; for example: "{01234567-0123-4567-89AB-CDEF01234567}".
Monitored
Data type: booleanAccess type: Read/Write
Required. Specifies whether a Performance Counter instance is created.
NextUpdateTS
Data type: sint32Access type: Read/Write
Required. Specifies the next update for the field. This is set to the current time (DateTime.Now) plus one day when the current time is greater than this value.
This is used for purging purposes.
Required.
Subnet
Data type: sint32Access type: Read/Write
Required. The subnet obtained from applying a single subnet mask.
Remarks
This class gets and sets information at the following level: SQL.
Instances of this class support the following interface methods:
Provider::DeleteInstance();
Provider::GetObject();
Provider::PutInstance();
Where PutInstance() supports the following flags:
WBEM_FLAG_CREATE_ONLY
WBEM_FLAG_UPDATE_ONLY
WBEM_FLAG_CREATE_OR_UPDATE
Requirements
Server: Installed on computers serving the following role: Monitoring Server.
Namespace: Defined in \root\cimv2.