MSFT_SIPMCUFactorySetting class
Communications Server 2007 Server SDK Documentation |
MSFT_SIPMCUFactorySetting
Defines a Media Control Unit (MCU) factory to manage MCUs.
The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties. Properties are listed in alphabetic order, not MOF order.
class MSFT_SIPMCUFactorySetting { string FactoryURL; [key] string InstanceID; uint32 MajorVersion; string MCUFactoryDN; string MCUFactoryProviderID; string[] MCUList; uint32 MinorVersion; string[] PoolList; string Type; string Vendor; };
Methods
This class does not define any methods.
Properties
The MSFT_SIPMCUFactorySetting class has the following properties.
FactoryURL
Data type: stringAccess type: Read-only
Required. Indicates the URL of the factory with which the Focus server communicates.
InstanceID
Data type: [key] stringAccess type: Read-only
Required. A GUID value that uniquely identifies an instance of this class.
The GUID must be encapsulated between the "{" and "}" braces; for example: "{01234567-0123-4567-89AB-CDEF01234567}".
MajorVersion
Data type: uint32Access type: Read-only
Required. The major Office Communications Server version number.
Value Description 2 Office Live Communications Server 2005 3 Office Communications Server 2007 The default value is 3.
MCUFactoryDN
Data type: stringAccess type: Read-only
Required. The distinguished name of the MCU factory.
MCUFactoryProviderID
Data type: stringAccess type: Read-only
Required. Indicates the GUID of the MCU factory provider.
MCUList
Data type: string[]Access type: Read-only
Optional. An array of the distinguished names of the MCU objects that this factory manages.
MinorVersion
Data type: uint32Access type: Read-only
Required. The minor Office Communications Server version number.
Value Description 0 Original release to market 1 Service Pack 1 release The default value is 0.
PoolList
Data type: string[]Access type: Read-only
Optional. An array of the distinguished names of the pools that this factory serves.
Type
Data type: stringAccess type: Read-only
Required. Indicates the type of the MCU factory.
Indicates, for example, if the factory is a data MCU factory, or an audio-video MCU factory.
Vendor
Data type: stringAccess type: Read-only
Required. Specifies the name of the MCU vendor.
Remarks
This class gets and sets information at the following level(s): AD.
Instances of this class support the following interface methods:
- Provider::EnumerateInstances();
- Provider::GetObject();
- Provider::PutInstance();
Requirements
Server: Installed on computers serving the following role(s): Administrative Tools Server, Audio/Video Conferencing Server, Front End Server, Proxy Server, Web Components Server, Web Conferencing Server.
Namespace: Defined in \root\cimv2.
See Also
Communications Server WMI Reference
What did you think of this topic? |
© 2007 Microsoft Corporation. All rights reserved. |