SMS_PowerAgentConfig Server WMI Class
Applies To: System Center 2012 Configuration Manager, System Center 2012 Configuration Manager SP1, System Center 2012 R2 Configuration Manager
The SMS_PowerAgentConfig Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that specifies power management settings on client computers.
The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.
Syntax
Class SMS_PowerAgentConfig : SMS_ClientAgentConfig_BaseClass
{
UInt32 AgentID;
Boolean AllowUserToOptOutFromPowerPlan;
Boolean Enabled;
Boolean EnableP2PWakeupSolution; (obsolete in SP1)
Boolean EnableWakeupProxy;
Boolean EnableUserIdleMonitoring;
UInt32 MaxCPU;
UInt32 MaxMachinesPerManager;
UInt32 MinimumServersNeeded;
UInt32 NumOfDaysToKeep;
UInt32 NumOfMonthsToKeep;
UInt32 Port;
UInt32 WakeupProxyDirectAccessPrefixList;
UInt32 WakeupProxyFirewallFlags;
UInt32 WolPort;
};
Methods
The SMS_PowerAgentConfig class does not define any methods.
Properties
AgentID
Data type: UInt32Access type: Read-only
Qualifiers: [key, read]
Identifies the client agent component. The Power Management Agent ID is 18.
AllowUserToOptOutFromPowerPlan
Data type: BooleanAccess type: Read/Write
Qualifiers: none
true to allow users to exclude their device from power management.
Enabled
Data type: BooleanAccess type: Read/Write
Qualifiers: none
true if the agent is enabled.
EnableP2PWakeupSolution
Data type: BooleanAccess type: Read/Write
Qualifiers: none
This method/property has been removed or deprecated in System Center Configuration Manager SP1.
EnableWakeupProxy
Data type: BooleanAccess type: Read/Write
Qualifiers: none
EnableWakeupProxy.
This information applies to System Center 2012 Configuration Manager SP1 or later, and System Center 2012 R2 Configuration Manager or later.
EnableUserIdleMonitoring
Data type: BooleanAccess type: Read/Write
Qualifiers: none
true if user idle status needs to be monitored. The default value is true.
MaxCPU
Data type: UInt32Access type: Read/Write
Qualifiers: none
Reserved for future use.
MaxMachinesPerManager
Data type: UInt32Access type: Read/Write
Qualifiers: none
Reserved for future use.
MinimumServersNeeded
Data type: UInt32Access type: Read/Write
Qualifiers: none
Reserved for future use.
NumOfDaysToKeep
Data type: UInt32Access type: Read/Write
Qualifiers: none
Maximum number of days that power data will be kept on the client computer. The default value is 31.
NumOfMonthsToKeep
Data type: UInt32Access type: Read/Write
Qualifiers: none
Maximum number of months that power data will be kept on the client computer. The default value is 13.
Port
Data type: UInt32Access type: Read/Write
Qualifiers: none
Reserved for future use.
WakeupProxyDirectAccessPrefixList
Data type: UInt32Access type: Read/Write
Qualifiers: none
WakeupProxyDirectAccessPrefixList.
This information applies to System Center 2012 Configuration Manager SP1 or later, and System Center 2012 R2 Configuration Manager or later.
WakeupProxyFirewallFlags
Data type: UInt32Access type: Read/Write
Qualifiers: none
WakeupProxyFirewallFlags.
This information applies to System Center 2012 Configuration Manager SP1 or later, and System Center 2012 R2 Configuration Manager or later.
WolPort
Data type: UInt32Access type: Read/Write
Qualifiers: none
Reserved for future use.
Remarks
Requirements
Runtime Requirements
For more information, see Configuration Manager Server Runtime Requirements.
Development Requirements
For more information, see Configuration Manager Server Development Requirements.