IsFutureWindowAvailable Method in Class CCM_ServiceWindowManager
Applies To: System Center 2012 Configuration Manager, System Center 2012 Configuration Manager SP1, System Center 2012 R2 Configuration Manager
The IsFutureWindowAvailable WMI class method, in Configuration Manager, determines whether a service window of a specified type and the given duration is going to be available.
The following syntax is simplified from Managed Object Format (MOF) code and defines the method.
Syntax
uint32 IsFutureWindowAvailable(
[IN] UInt32 ServiceWindowType,
[IN] Boolean FallbackToAllProgramsWindow,
[IN] UInt32 MaxRuntime,
[OUT] Boolean WillProgramRunInFuture
);
Parameters
ServiceWindowType
Data type: UInt32Qualifiers: [in]
Type of service window. The following table lists the possible values.
Value
Service Window Type
Description
1
ALLPROGRAM_SERVICEWINDOW
All Programs Service Window
2
PROGRAM_SERVICEWINDOW
Program Service Window
3
REBOOTREQUIRED_SERVICEWINDOW
Reboot Required Service Window
4
SOFTWAREUPDATE_SERVICEWINDOW
Software Update Service Window
5
OSD_SERVICEWINDOW
OSD Service Window
6
USER_DEFINED_SERVICE_WINDOW
Corresponds to non-working hours.
FallbackToAllProgramsWindow
Data type: BooleanQualifiers: [in]
true if the generic All programs window service window is to be used when a window specified in ServiceWindowType is not available; otherwise, false.
MaxRuntime
Data type: UInt32Qualifiers: [in]
Maximum run time, in minutes, that a software update installation has to complete before the installation is no longer monitored by Configuration Manager. This setting is also used to determine whether there is enough time to install the update before the end of a maintenance window. The default setting is 60 minutes for service packs and 5 minutes for all other software update types. Values can range from 5 to 9999 minutes.
Important
Make sure that the maximum run time value is not set for more time than the configured maintenance window or the software update installation will not initiate.
WillProgramRunInFuture
Data type: BooleanQualifiers: [out]
true if the specified service window is going to be available; otherwise, false.
Return Values
A UInt32 data type that is 0 to indicate success or nonzero to indicate failure.
For information about handling returned errors, see About Configuration Manager Errors.
Remarks
Requirements
Runtime Requirements
For more information, see Configuration Manager Client Runtime Requirements.