BeforeBand Event
Occurs just before the Report System begins processing a report band.
PROCEDURE Object.BeforeBand
LPARAMETERS nBandObjCode, nFRXRecNo
Parameters
Visual FoxPro passes the BeforeBand event parameters in the following order:
nBandObjCode
Integer data type, specifying the type of band, as stored in the ObjCode field of the report or label definition file (frx or lbx).Recognized numeric values for nBandObjCode are documented in the 60FRX.DBF table in the FILESPEC directory, as follows:
0
Title
1
Page Header
2
Column Header
3
Group Header
4
Detail
5
Group Footer
6
Column Footer
7
Page Footer
8
Summary
9
Detail Header
10
Detail Footer
For more information about 60FRX, see Table Structures of Table Files (.dbc, .frx, .lbx, .mnx, .pjx, .scx, .vcx).
- nFRXRecno
Integer data type, specifying the record number in the report or label definition file (frx or lbx) describing the layout element being rendered.
Remarks
Applies To: ReportListener Object.
For each band in the report, the ReportListener triggers the BeforeBand event before the Report Engine runs any code in the OnEntry expression. It triggers the AfterBand event after any OnExit code runs.
Note
For information about the order of events in a report run, see Understanding Visual FoxPro Object-Assisted Reporting.
See Also
Tasks
How to: Specify Expressions to Evaluate When Processing Bands
Reference
ReportListener Object
AfterBand Event