CESTRESS Return Value
Other versions of this page are also available for the following:
8/27/2008
This enumeration specifies return values for an iteration of a test module in the Windows Embedded CE Stress tool.
Syntax
enum CESTRESS return value {
CESTRESS_PASS,
CESTRESS_FAIL,
CESTRESS_WARN1,
CESTRESS_WARN2,
CESTRESS_ABORT
};
Elements
- CESTRESS_PASS
An iteration of the test module succeeded.
- CESTRESS_FAIL
The subject of the test failed to perform as expected.
- CESTRESS_WARN1
A problem occurred, but the problem is likely external to the subject of the test. The cause of the problem is unknown. For example, the test may have lost connection to a server that returned an ambiguous error code.
- CESTRESS_WARN2
A minor failure occurred in the test module, likely because of temporary, expected external circumstances. For example, the test module might not be able to connect to a server because the server reports that it has exceeded a limit on the number of connections. Alternatively, the test module might not be able to access a resource such as a file with the exclusive access rights the test module requires, because another process owns the resource.
- CESTRESS_ABORT
Value that causes the harness to attempt to unload the test module.
Requirements
Header | stressutils.h |
Windows Embedded CE | Windows CE .NET 4.2 and later |