IMsTscNonScriptable::ResetPassword (Windows Embedded CE 6.0)
1/6/2010
This method resets all password states in the Remote Desktop ActiveX control. Call this method to clear passwords that are stored in any one of the three supported formats: clear text, portable encoded, or binary (non-portable) encoded.
Syntax
HRESULT ResetPassword();
Parameters
None.
Return Value
The following table shows the return values for this method.
Value | Description |
---|---|
S_OK |
Virtual channel was correctly created. |
E_FAIL |
The control is already connected or in the connecting state. |
nonzero error code |
An error occurred. |
Remarks
You can call this method to reset the control's password after disconnecting. This ensures that subsequent connections that use the same instance of the control do not automatically log on with a previously set password.
You can only call this method if the control is not in the connected state. The method returns E_FAIL if called when the control is connected. You can check if the control is connected by calling the IMsTscAx::get_Connected interface.
Requirements
Header | discodlg.h, mstsax.idl |
Library | Mstsax.lib |
Windows Embedded CE | Windows CE .NET 4.0 and later |