OID_DOT11_SHORT_SLOT_TIME_OPTION_IMPLEMENTED (Compact 2013)

3/26/2014

When queried, this OID requests that the miniport driver return the value of the IEEE 802.11g dot11ShortSlotTimeOptionImplemented management information base (MIB) object for the current PHY type on the 802.11 station.

This MIB object specifies whether the current PHY type supports the 802.11g short slot time option. For more information about the short slot time, refer to Clause 7.3.1.4 of the IEEE 802.11g‑2003 standard.

The data type for this OID is a BOOLEAN value. A value of TRUE indicates that the current PHY type supports the 802.11g short slot time option.

The dot11ShortSlotTimeOptionImplemented MIB object is only valid for the Extended Rate PHY (ERP) type. If the current PHY type is not set to dot11_phy_type_erp, the miniport driver must fail the query request by returning NDIS_STATUS_INVALID_DATA from its MiniportOidRequest function.

If the miniport driver is operating in Extensible Station (ExtSTA) mode, the current PHY type is determined through the ExtSTA msDot11CurrentPhyID MIB object. This MIB object specifies the index of the current PHY type within the 802.11 station’s list of supported PHY types. For more information about this MIB object, see OID_DOT11_CURRENT_PHY_ID.

Requirements

Header

windot11.h

See Also

Reference

NDIS 5.x Legacy Wireless LAN OIDs
MiniportOidRequest
OID_DOT11_CURRENT_PHY_ID
Native 802.11 MIB OIDs