LINECONFIGDATA (Windows Embedded CE 6.0)
1/6/2010
This structure specifies the configuration information for a modem line. It is used by the Unimodem Configuration dialog box.
Syntax
typedef struct _LINECONFIGDATA {
DWORD dwVersion;
DWORD dwBaudRate;
DWORD dwSettableBaud;
BYTE bByteSize;
BYTE bParity;
BYTE bStopBits;
BYTE bReserved;
WORD wSettableData;
WORD wWaitBong;
DWORD dwCallSetupFailTimer;
DWORD dwModemOptions;
DWORD dwTermOptions;
DWORD dwDdevCapFlags;
DWORD dwModMaxLen;
TCHAR szDialModifier[NETUI_LCD_DIAL_MOD_LEN + 1];
WORD wSettableStopParity;
} LINECONFIGDATA, *PLINECONFIGDATA;
Members
- dwVersion
Specifies the version of the structure.
- dwBaudRate
Specifies the baud rate of the connection, using CBR_* values listed in %_WINCEROOT%\Public\Sdk\Inc\Winbase.h, for example, CBR_110.
- dwSettableBaud
Specifies the baud rates, using BAUD_* bit values from %_WINCEROOT%\Public\Sdk\Inc\Winbase.h.
- bByteSize
Specifies the number of bits per byte, which can be from 4 to 8.
bParity
Specifies the parity of the connection. The following table shows the parity settings.Setting Parity 0
None
1
Odd
2
Even
3
Mark
4
Space
bStopBits
Specifies the number of stop bits. The following table shows the settings for stop bits.Setting Stop bits 0
1 stop bit
1
1.5 stop bits
2
2 stop bits
- bReserved
Used for alignment purposes.
wSettableData
Indicates the number of data bits to be sent. The following table shows the supported values.Value Description DATABITS_5
5 data bits
DATABITS_6
6 data bits
DATABITS_7
7 data bits
DATABITS_8
8 data bits
DATABITS_16
16 data bits
DATABITS_16X
Special wide path through serial hardware lines
- wWaitBong
Specifies the number of seconds to wait for a credit-card tone.
- dwCallSetupFailTimer
Specifies the dial timeout value.
dwModemOptions
Specifies modem options. The following table shows the supported modem options.Value Description NETUI_LCD_MDMOPT_SOFT_FLOW
Software flow control
NETUI_LCD_MDMOPT_HARD_FLOW
Hardware flow control
NETUI_LCD_MDMOPT_BLIND_DIAL
Blind dial
NETUI_LCD_MDMOPT_AUTO_BAUD
Enables DCC automatic baud rate detection
dwTermOptions
Specifies the terminal type. The following table shows the supported terminal types.Terminal option Terminal type NETUI_LCD_TRMOPT_MANUAL_DIAL
Manual dial
NETUI_LCD_TRMOPT_PRE_DIAL
Predial
NETUI_LCD_TRMPOT_POST_DIAL
Postdial
- dwDdevCapFlags
Not supported.
- dwModMaxLen
Specifies the length to allow user to edit. The length is the value specified for NETUI_LCD_DIAL_MOD_LEN.
- szDialModifier
Specifies an optional modem command that is issued just after the modem has been initialized and just before the phone number is to be dialed.
wSettableStopParity
Specifies the stop bit and parity settings that can be selected. The following table shows the supported values.Value Description PARITY_EVEN
Even parity
PARITY_MARK
Mark parity
PARITY_NONE
No parity
PARITY_ODD
Odd parity
PARITY_SPACE
Space parity
STOPBITS_10
1 stop bit
STOPBITS_15
1.5 stop bits
STOPBITS_20
2 stop bits
Requirements
Header | netui.h |