The Config key contains commands for configuring various modem settings. The values under this key override corresponding members of the DevConfig structure.
The following table shows the named values for the HKEY_LOCAL_MACHINE\Drivers\PCMCIA\CompanyX-GenericModem-1234\Unimodem\Config key.
Value : type | Description |
---|---|
BaudRate : REG_DWORD |
Specifies the default baud rate for the device, usually 19200. |
ByteSize |
Specifies the byte size for the device, usually 8. |
CallSetupFailTimer : REG_DWORD |
Specifies the default number of seconds for connection establishment, usually 120. |
DialModifier : REG_SZ |
Specifies the modem command string to be issued immediately before the dial command. This value usually is not specified. |
EnableAutoBaud : REG_DWORD |
Enables or disables auto-baud rate detection for direct serial connection devices. This value is usually set to 0, which disables auto-baud rate detection. |
EnableBlindDial : REG_DWORD |
Enables or disables blind dial functionality. This value is usually set to 0, which disables blind dial. |
EnableFlowHard : REG_DWORD |
Enables or disables hardware flow control. This value is usually set to 1, which enables hardware flow control. |
EnableFlowSoft : REG_DWORD |
Enable or disable software flow control. This value is usually set to 0, which disables software flow control. |
EnableToneDial : REG_DWORD |
Enables or disables tone dial functionality. This value is usually set to 1, which enables tone dial functionality. |
ManualDial : REG_DWORD |
Enables or disables manual dial terminal window. This value is usually set to 0, which disables the manual dial terminal window. |
Parity : REG_DWORD |
Specifies one of the parity modes that are defined in Winbase.h in the %_WINCEROOT%\Public\common\sdk\inc directory. This value is usually set to 0, which means that no parity mode is specified. |
PostDialTerminal : REG_DWORD |
Enables or disables post-dial terminal window. This value is usually set to 0, which disables the post-dial terminal window. |
PreDialTerminal : REG_DWORD |
Enables or disables pre-dial terminal window. This value is usually set to 0, which disables the pre-dial terminal window. |
StopBits : REG_DWORD |
Specifies one of the stop bits modes that are defined in Winbase.h. This value is usually set to 0, which specifies 1 stop bit. |
WaitBong : REG_WORD |
Specifies the seconds to wait for prompt tone. This value is usually set to 0. |