DF - PNP Rebalance Fail Restart Device Test (Functional)
This test uses EDT filter driver to try and cause IRP_MN_STOP_DEVICE to be sent to target device stacks. The EDT filter driver then fails IRP_MN_START_DEVICE requests (that follow IRP_MN_STOP_DEVICE requests) to trigger surprise removal of target devices.
For information included in the Windows Driver Kit on this test, see PnP Tests (Device Fundamentals) (Windows Drivers).
Test details
Associated requirements |
Device.DevFund.Reliability.Discretional |
Platforms |
Windows RT 8.1 Windows 8.1 x64 Windows 8.1 x86 Windows Server 2012 R2 |
Expected run time |
~3 minutes |
Categories |
Functional |
Type |
Automated |
Running the test
Before you run the test, complete the test setup as described in the test requirements: Device.Fundamentals Reliability Testing Prerequisites.
Troubleshooting
For troubleshooting information, see Troubleshooting Device Fundamentals Reliability Testing by using the Windows HCK.
More information
Parameters
Parameter | Description |
---|---|
WDTFREMOTESYSTEM |
This parameter is required only if the device under test, or one of its child devices, is a wired network adapter that does not have an IPv6 gateway address. If this parameter is required on your network, you must provide an IPv6 address that the test network adapter can ping to test network. Example: fe80::78b6:810:9c12:46cd |
Wpa2PskAesSsid |
This parameter is required only if the device under test or one of its child devices is a WiFi adapter. Provide the SSID of a WPA2 AES WiFi network that the test can use to test the WiFi adapter. Default value: kitstestssid |
Wpa2PskPassword |
This parameter is required only if the device under test or one of its child devices is a WiFi adapter. Provide password of the WPA2 AES WiFi network that is specified by using the Wpa2PskAesSsid parameter. Default value: password |