Device Width
Test name
Test.DeviceWidth.json
Core requirements tested
Device.Digitizer.PrecisionTouchPad.Hardware.Width
Test purpose
Verifies that the device sensor meets or exceeds minimum width requirement of 64mm.
Tools required
PTLogo.exe
Ruler or micrometer
Validation steps
Start Test.DeviceWidth.json.
Measure touchpad width with a ruler or micrometer.
Assuming X is the reported sensor width, verify the following:
The measured device width is between X and (X + 4).
X is >= 64mm.
If these conditions are true, then manually pass the iteration; otherwise, manually fail the iteration.
Note
Because the sensor might be slightly smaller than the cover sheet, the measured width can be as much as 4mm greater than that which is reported by the device.
Common errors
None
Passing
1/1 (100%) iterations must pass in order to complete with passing status.