Supported storage arrays
Virtualized workloads in System Center Virtual Machine Manager (VMM) need storage resources that meet capacity and performance requirements. VMM recognizes local and remote storage. It supports storage on block-level storage devices that expose logical unit numbers (LUNs) using fiber channel, iSCSCI, SAS connections, and network file shares.
This article provides a list of supported storage devices for VMM 2016.
Device | Protocol | Min Controller Firmware | SMI-S | Details |
---|---|---|---|---|
Hewlett Packard Enterprise 3PAR |
SMI-S | 3PAR: 3PAR v. 3.2.2 MU3 or later 3PAR 8000 & 20000, 7000 & 10000 |
SMI-S CIM version 1.5 | Link |
Tintri VMstore |
SMB | 4.2 and later | Embedded version 2.1 | Support |
NEC / NEC Storage M-Series M310, M510, M710, M310F, M710F, M320, M320F |
iSCSI/FC | Min Controller Firmware: 010A(Storage Control Software Revision 0941 or later) | SMI-S v1.6.1 | Details |
Fujitsu/ETERNUS DX60 S3, DX60 S4, DX100 S3, DX100 S4, DX200 S3, DX200 S4 DX500 S3, DX500 S4, DX600 S3, DX600 S4, DX8700 S3, DX8900 S3, DX8900 S4, DX200F, AF250, AF250 S2, AF650, AF650 S2 |
iSCSI/FC | V10L60 or later | EMBEDDED SMI-S v1.6.0 | Storage System ETERNUS |
DELL-EMC XtremIO All Flash Array |
iSCSI/FC | XtremIO XMS Server Versions: 4.2.0 and 4.2.1 | Embedded SMI-S V1.6.1 | Link |
DELL SC Series |
iSCSI/FC | SCOS: 7.2 or later DSM: 2016 R3 or later SCOS 7.3.5 or later, DSM 2018 R1.20 or later SCOS 7.4.x and later, DSM 2020 R1 (20.1.1) or later |
SMI-S version 1.6 |
Link |
NetApp FAS |
iSCSI/FC/SMB | 8.2 and later | Proxy NetApp SMIS Provider 5.2.4 or later | Link |
Huawei OceanStor V3 Series |
iSCSI/FC | V300R006 and later | Huawei SMI-S version 2.1.01 or later |
OceanStor 2200 V3 OceanStor 2600 V3 |
Huawei OceanStor Dorado V3 Series |
iSCSI/FC | V300R001 and later | Huawei SMI-S version 2.1.01 or later |
Link |
Huawei OceanStor V5 Series |
iSCSI/FC | V500R007 and later | Huawei SMI-S Provider v 2.1.03 and later |
OceanStor 2200 V5 OceanStor 2600 V5 |
IBM XIV Storage System Gen3 |
iSCSI/FC | 11.6.0 and later | embedded SMI-S v1.6.1 |
Link |
IBM FlashSystem A9000/A9000R |
iSCSI/FC | 12.1.0 and later | embedded SMI-S v1.6.1 |
Link |
IBM Spectrum Virtualize Family Product - SAN Volume Controller(SVC)/Storwize V7000, Storwize V5000, IBM FlashSystem V9000 |
iSCSI/FC | 7.8.0 and later | embedded SMI-S v1.6.1 |
Link |
Pure Storage FlashArray M |
iSCSI/FC | Purity 4.9 and later | SMI-S v1.6.1 |
Link |
DELL-EMC PS Series |
iSCSI | PS Firmware: v8.1 or later HIT Kit: v5.1 or later |
SMP v5.1 | Link |
This article provides details of the supported arrays for System Center 2019 - Virtual Machine Manager (VMM).
Supported storage arrays in VMM 2019
Virtualized workloads in System Center - Virtual Machine Manager (VMM) need storage resources that meet capacity and performance requirements. VMM recognizes local and remote storage. It supports storage on block-level storage devices that expose logical unit numbers (LUNs) using fiber channel, iSCSCI, and SAS connections, and network file shares.
Device | Protocol | Min Controller Firmware | SMI-S | Details |
---|---|---|---|---|
Hewlett Packard Enterprise 3PAR |
SMI-S | 3PAR: 3PAR v. 3.2.2 MU3 or later 3PAR 8000 & 20000, 7000 & 10000 |
SMI-S CIM version 1.5 | Link |
NEC / NEC Storage M-Series M320, M320F, M520, M720, M720F | iSCSI/FC | 010A M320/M320F Storage Control Software revision 1028 or later M520/M720/M720F Storage Control Software revision 1224 or later |
SMI-S 1.6.1 | Link |
DELL SC Series |
iSCSI/FC | SCOS: 7.4.2 or later DSM: 2019 R1 or later DSM 2020 R1 (20.1.1) or later |
SMI-S version 1.6 |
Link |
HPE Primera |
SMI-S | 4.0.0 | 4.0.0 | Link |
Pure Storage FlashArray - X, C, M |
iSCSI/FC | Purity 5.3.0+ 6.0.0+ and 6.1.0+ | version 1.6.1 | Link |
Note
Known issue: Deletion of thinly provisioned storage volume (LUN) fails for HPE Primera through VMM 2019.
Workaround: Delete LUN directly from the array.
This article provides details of the supported arrays for System Center 2022 - Virtual Machine Manager (VMM).
Supported storage arrays in VMM 2022
Virtualized workloads in System Center - Virtual Machine Manager (VMM) need storage resources that meet capacity and performance requirements. VMM recognizes local and remote storage. It supports storage on block-level storage devices that expose logical unit numbers (LUNs) using fiber channel, iSCSCI, and SAS connections, and network file shares.
Device | Protocol | Min Controller Firmware | SMI-S | Details |
---|---|---|---|---|
Hewlett Packard Enterprise 3PAR |
SMI-S | 3PAR: 3PAR v. 3.2.2 MU3 or later 3PAR 8000 & 20000, 7000 & 10000 |
SMI-S CIM version 1.5 | Link |
NEC / NEC Storage M-Series M320, M320F, M520, M720, M720F | iSCSI/FC | 010A M320/M320F Storage Control Software revision 1028 or later M520/M720/M720F Storage Control Software revision 1224 or later |
SMI-S 1.6.1 | Link |
DELL SC Series |
iSCSI/FC | SCOS: 7.4.2 or later DSM: 2019 R1 or later DSM 2020 R1 (20.1.1) or later |
SMI-S version 1.6 |
Link |
HPE Primera |
SMI-S | 4.0.0 | 4.0.0 | Link |
Pure Storage FlashArray - X, C, M |
iSCSI/FC | Purity 5.3.0+ 6.0.0+ and 6.1.0+ | version 1.6.1 | Link |
Note
Known issue: Deletion of thinly provisioned storage volume (LUN) fails for HPE Primera through VMM 2022.
Workaround: Delete LUN directly from the array.
Note
If you would like us to certify a new storage device, reach out to systemcenterfeedback@microsoft.com.
Next steps
- Learn more about configuring storage in the VMM fabric.
- Learn more about array SMI-S Conformance Testing Program