This article helps you resolve the problem that occurs when you use eConnect for Dynamics GP 2010 or the eConnect destination adapter in Integration Manager.
Applies to: Microsoft Dynamics GP
Original KB number: 2539263
Symptoms
You may receive the following error message intermittently when you use eConnect for Dynamics GP 2010 or the eConnect destination adapter in Integration Manager:
There was an error writing to the pipe: The pipe is being closed.
Cause
The eConnect for Microsoft Dynamics GP 2010 Integration Service is a WCF service. A connection can remain inactive, during which no application messages are received, before it is dropped after 10 minutes. This is by default.
Resolution
Add receiveTimeout="infinite" to the Microsoft.Dynamics.GP.eConnect.Service.exe.config file for the eConnect Integration service. The binding section should resemble this:
<binding name="eConnectNamedPipeConfig" closeTimeout="00:10:00" sendTimeout="00:10:00" receiveTimeout ="infinite" transferMode="Buffered" hostNameComparisonMode="StrongWildcard" maxBufferPoolSize="2147483647" maxBufferSize="2147483647" maxReceivedMessageSize="2147483647"><readerQuotas maxDepth="60" maxStringContentLength="2147483647"maxArrayLength="2147483647" maxBytesPerRead="2147483647" maxNameTableCharCount="2147483647" /><security mode="Transport"><transport protectionLevel="EncryptAndSign" /></security>
</binding>