"Operation must use an updateable query" error when you run an integration in Integration Manager

This article provides a resolution for the issue that you can't run an integration in Integration Manager for Microsoft Dynamics GP due to the Operation must use an updateable query error.

Applies to:   Microsoft Dynamics GP
Original KB number:   968361

Symptoms

When you run an integration in Integration Manager for Microsoft Dynamics GP, you receive the following error message:

Operation must use an updateable query.

Cause

This issue occurs when you have insufficient Windows permissions to read and to write to the location where the Integration database or the source files are stored.

Resolution

You must have the Modify permission for the location of Integration Manager and the source files. This lets you edit, create, and delete the existing files.

To resolve this issue, follow these steps:

  1. Right-click the folder where the Integration database and the source files are located, and then select Properties.
  2. Select the Security tab.
  3. Under Group or user names, select the user or the group that is experiencing the issue.
  4. Under Permissions forUser Name, make sure that the Modify check box is selected in the Allow column.
  5. Select OK to save the changes.