Note
Access to this page requires authorization. You can try signing in or changing directories.
Access to this page requires authorization. You can try changing directories.
This is to test the reporting area coverage of a Windows Precision Touchpad device.
Test name
- Test.AllAreas.json
Core requirements tested
- Device.Input.Digitizer.PrecisionTouchpad.Accuracy
Test purpose
- Verifies that the device can report contacts in all areas of the digitizer surface.
Tools required
- PTLogo.exe
Validation steps
Launch Test.AllAreas.json.
Following the directions on the screen, you will perform 5 taps in each general region of the touchpad (top-left, top-right, bottom-left, bottom-right, and center): a. Tap anywhere inside the specified region. For example, if top-left is specified, tap anywhere left of center and above the middle of the touchpad.
i. Tap a different random location for each of the 5 iterations.
ii. If the tap occurs in the expected region, PTLogo will automatically pass the iteration.
iii. If no tap is registered for a given region, manually fail the iteration.
b. After 5 taps, the onscreen instructions will indicate the next region to tap. Repeat the preceding Step 2.a for each subsequent region as indicated. Common error messages
- None.
Passing criteria
- 25/25 (100%) iterations must pass in order to complete with passing status.