Set Energy Source Lifetime Warning Threshold (Function Index 8)

This _DSM Interface for Byte Addressable Energy Backed Function Class (Function Interface 1) function sets the warning threshold for remaining Energy Source (ES) lifetime percentage. This function may return a failure status if the ES is host-managed and the platform doesn't support thresholds.

Registers are defined in the Byte Addressable Energy Backed Interface specification.

Input

Arg3

Field Byte length Byte offset Description
ES Lifetime Percentage Warning Threshold 1 0 The percentage value of the warning threshold, which must be between 0 and 100. The platform shall write this value to the ES_LIFETIME_WARNING_THRESHOLD (0, 0x99) register.

Output

Field Byte length Byte offset Register Description
Status 4 0 This function can return the following Function-Specific Error Code: The platform does not support ES thresholds. For more information, see _DSM Method Output.

Set Energy Source Temperature Warning Threshold (Function Index 9)

Get Energy Source Thresholds (Function Index 7)