NumberOfRuns
Indicates the number of times that an on-off transition is run.
Element Hierarchy
- <WindowsPerformanceRecorder>
- <OnOffTransitionConfigurations>
- <OnOffTransitionConfiguration>
- <NumberOfRuns>
- <OnOffTransitionConfiguration>
- <OnOffTransitionConfigurations>
Syntax
<NumberOfRuns Value = SimpleValueType>
</NumberOfRuns>
Attributes and Elements
Attributes
Attribute | Description | Data type | Required | Default |
---|---|---|---|---|
Value | Number of times the on/off transition is run. | Integer value equal to or greater than 1. | Yes |
Child Elements
None.
Parent Elements
Element | Description |
---|---|
OnOffTransitionConfiguration | Represents on on/off transition configuration. |
Example
The following code example shows how to configure this element.
<OnOffTransitionConfiguration
Id="OnOffTransitionConfiguration_Default_Boot"
Name="OnOffTransitionConfiguration_Default_Boot"
Type="On/Off - Boot">
<PrepareSystem Value="true"/>
<NumberOfRuns Value="3"/>
<PostBootDelay Value="120"/>
<WakeupDelay Value="60"/>
<TransitionTag Value="Boot"/>
</OnOffTransitionConfiguration>