Note
Access to this page requires authorization. You can try signing in or changing directories.
Access to this page requires authorization. You can try changing directories.
Windows Filtering Platform (WFP) specific error codes are as follows.
-
FWP_E_CALLOUT_NOT_FOUND
-
-
0x80320001
-
The callout does not exist.
-
-
FWP_E_CONDITION_NOT_FOUND
-
-
0x80320002
-
The filter condition does not exist.
-
-
FWP_E_FILTER_NOT_FOUND
-
-
0x80320003
-
The filter does not exist.
-
-
FWP_E_LAYER_NOT_FOUND
-
-
0x80320004
-
The layer does not exist.
-
-
FWP_E_PROVIDER_NOT_FOUND
-
-
0x80320005
-
The provider does not exist.
-
-
FWP_E_PROVIDER_CONTEXT_NOT_FOUND
-
-
0x80320006
-
The provider context does not exist.
-
-
FWP_E_SUBLAYER_NOT_FOUND
-
-
0x80320007
-
The sub-layer does not exist.
-
-
FWP_E_NOT_FOUND
-
-
0x80320008
-
The object does not exist.
The IPsecSaContext* functions return this error if the SA context ID is not found.
-
-
FWP_E_ALREADY_EXISTS
-
-
0x80320009
-
An object with that GUID or LUID already exists.
-
-
FWP_E_IN_USE
-
-
0x8032000A
-
The object is referenced by other objects, so it cannot be deleted.
-
-
FWP_E_DYNAMIC_SESSION_IN_PROGRESS
-
-
0x8032000B
-
The call is not allowed from within a dynamic session.
-
-
FWP_E_WRONG_SESSION
-
-
0x8032000C
-
The call was made from the wrong session, so it cannot be completed.
-
-
FWP_E_NO_TXN_IN_PROGRESS
-
-
0x8032000D
-
The call must be made from within an explicit transaction.
-
-
FWP_E_TXN_IN_PROGRESS
-
-
0x8032000E
-
The call is not allowed from within an explicit transaction.
-
-
FWP_E_TXN_ABORTED
-
-
0x8032000F
-
The explicit transaction has been forcibly canceled.
-
-
FWP_E_SESSION_ABORTED
-
-
0x80320010
-
The session has been canceled.
The session handle needs to be closed by calling FwpmEngineClose0, even though it is no longer valid; otherwise, the client-side state will be leaked. A new session should be created by calling FwpmEngineOpen0.
-
-
FWP_E_INCOMPATIBLE_TXN
-
-
0x80320011
-
The call is not allowed from within a read-only transaction.
-
-
FWP_E_TIMEOUT
-
-
0x80320012
-
The call timed out while waiting to acquire the transaction lock.
-
-
FWP_E_NET_EVENTS_DISABLED
-
-
0x80320013
-
The collection of network diagnostic events is disabled.
-
-
FWP_E_INCOMPATIBLE_LAYER
-
-
0x80320014
-
The operation is not supported by the specified layer.
-
-
FWP_E_KM_CLIENTS_ONLY
-
-
0x80320015
-
The call is allowed for kernel-mode callers only.
-
-
FWP_E_LIFETIME_MISMATCH
-
-
0x80320016
-
The call tried to associate two objects with incompatible lifetimes.
See Object Management for more information on object lifetime and object association.
-
-
FWP_E_BUILTIN_OBJECT
-
-
0x80320017
-
The object is built-in, so it cannot be deleted.
-
-
FWP_E_TOO_MANY_CALLOUTS
-
-
0x80320018
-
The maximum number of callouts has been reached.
At most, 100,000 callouts can be registered at the same time.
-
-
FWP_E_NOTIFICATION_DROPPED
-
-
0x80320019
-
A notification could not be delivered because a message queue is at its maximum capacity.
-
-
FWP_E_TRAFFIC_MISMATCH
-
-
0x8032001A
-
The network traffic parameters do not match those for the security association context.
IPsecSaContextGetSpi0 can be called multiple times, but the caller must specify the same IPSEC_TRAFFIC0 each time. This error is returned if a subsequent call supplies a different IPSEC_TRAFFIC0.
-
-
FWP_E_INCOMPATIBLE_SA_STATE
-
-
0x8032001B
-
The call is not allowed for the current security association (SA) state.
The SA context functions must be called in a specific order:
This error is returned if they are called out of order.
-
-
FWP_E_NULL_POINTER
-
-
0x8032001C
-
A required pointer is null.
-
-
FWP_E_INVALID_ENUMERATOR
-
-
0x8032001D
-
An enumerator value in a structure is out of range.
-
-
FWP_E_INVALID_FLAGS
-
-
0x8032001E
-
The flags field contains an invalid value.
-
-
FWP_E_INVALID_NET_MASK
-
-
0x8032001F
-
A network mask is not valid.
-
-
FWP_E_INVALID_RANGE
-
-
0x80320020
-
An FWP_RANGE0 structure is not valid.
-
-
FWP_E_INVALID_INTERVAL
-
-
0x80320021
-
The time interval is not valid.
-
-
FWP_E_ZERO_LENGTH_ARRAY
-
-
0x80320022
-
An array that must contain at least one element has zero length.
-
-
FWP_E_NULL_DISPLAY_NAME
-
-
0x80320023
-
The displayData.name field cannot be null.
-
-
FWP_E_INVALID_ACTION_TYPE
-
-
0x80320024
-
The action type is not one of the allowed action types for a filter.
-
-
FWP_E_INVALID_WEIGHT
-
-
0x80320025
-
The filter weight is not valid.
See Filter Weight Assignment for more information.
-
-
FWP_E_MATCH_TYPE_MISMATCH
-
-
0x80320026
-
A filter condition contains a match type that is not compatible with the operands.
See FWP_MATCH_TYPE for more information.
-
-
FWP_E_TYPE_MISMATCH
-
-
0x80320027
-
An FWP_VALUE0 structure or an FWPM_CONDITION_VALUE0 structure is of the wrong type.
-
-
FWP_E_OUT_OF_BOUNDS
-
-
0x80320028
-
An integer value is outside the allowed range.
-
-
FWP_E_RESERVED
-
-
0x80320029
-
A reserved field is nonzero.
-
-
FWP_E_DUPLICATE_CONDITION
-
-
0x8032002A
-
A filter cannot contain multiple conditions operating on a single field.
-
-
FWP_E_DUPLICATE_KEYMOD
-
-
0x8032002B
-
A policy cannot contain the same keying module more than once.
-
-
FWP_E_ACTION_INCOMPATIBLE_WITH_LAYER
-
-
0x8032002C
-
The action type is not compatible with the layer.
-
-
FWP_E_ACTION_INCOMPATIBLE_WITH_SUBLAYER
-
-
0x8032002D
-
The action type is not compatible with the sub-layer.
-
-
FWP_E_CONTEXT_INCOMPATIBLE_WITH_LAYER
-
-
0x8032002E
-
The raw context or the provider context is not compatible with the layer.
-
-
FWP_E_CONTEXT_INCOMPATIBLE_WITH_CALLOUT
-
-
0x8032002F
-
The raw context or the provider context is not compatible with the callout.
-
-
FWP_E_INCOMPATIBLE_AUTH_METHOD
-
-
0x80320030
-
The authentication method is not compatible with the policy type.
-
-
FWP_E_INCOMPATIBLE_DH_GROUP
-
-
0x80320031L
-
The Diffie-Hellman group is not compatible with the policy type.
-
-
FWP_E_EM_NOT_SUPPORTED
-
-
0x80320032
-
An IKE policy cannot contain an Extended Mode policy.
-
-
FWP_E_NEVER_MATCH
-
-
0x80320033
-
The enumeration template or subscription will never match any objects.
-
-
FWP_E_PROVIDER_CONTEXT_MISMATCH
-
-
0x80320034
-
The provider context is of the wrong type.
-
-
FWP_E_INVALID_PARAMETER
-
-
0x80320035
-
The parameter is incorrect.
Possible reasons for this error:
- FwpmIPsecTunnelAdd0 was called without setting the flag FWPM_TUNNEL_FLAG_POINT_TO_POINT and with conditions other than local/remote address.
- An invalid Unicode string, or a Unicode string that contains unprintable characters.
-
-
FWP_E_TOO_MANY_SUBLAYERS
-
-
0x80320036
-
The maximum number of sublayers has been reached.
WFP supports at most 2 6 sublayers.
-
-
FWP_E_CALLOUT_NOTIFICATION_FAILED
-
-
0x80320037
-
The notification function for a callout returned an error.
-
-
FWP_E_INVALID_AUTH_TRANSFORM
-
-
0x80320038
-
The IPsec authentication transform is not valid.
-
-
FWP_E_INVALID_CIPHER_TRANSFORM
-
-
0x80320039
-
The IPsec cipher transform is not valid.
-
Requirements
Requirement | Value |
---|---|
Minimum supported client |
Windows Vista [desktop apps only] |
Minimum supported server |
Windows Server 2008 [desktop apps only] |
Header |
|