Note
Access to this page requires authorization. You can try signing in or changing directories.
Access to this page requires authorization. You can try changing directories.
IPsec Task Offload v2 settings for a network adapter
The following syntax is simplified from Managed Object Format (MOF) code and includes all of the inherited properties.
Syntax
[Dynamic, Provider("NetAdapterCim")]
class MSFT_NetAdapterIPsecOffloadV2SettingData : MSFT_NetAdapterSettingData
{
string Caption;
string Description;
string ElementName;
string InstanceID;
string Name;
string InterfaceDescription;
uint32 Source;
string SystemName;
boolean Enabled;
boolean IPv6Supported;
boolean IPv4OptionsSupported;
boolean IPv6NonIPsecExtensionHeadersSupported;
boolean AhSupported;
boolean EspSupported;
boolean AhEspCombinedSupported;
boolean TransportSupported;
boolean TunnelSupported;
boolean LsoSupported;
uint32 UdpEspSupported;
uint32 AuthenticationAlgorithmsSupported;
uint32 EncryptionAlgorithmsSupported;
uint32 SaOffloadCapacitySupported;
boolean IPv6Enabled;
boolean IPv4OptionsEnabled;
boolean IPv6NonIPsecExtensionHeadersEnabled;
boolean AhEnabled;
boolean EspEnabled;
boolean AhEspCombinedEnabled;
boolean TransportEnabled;
boolean TunnelEnabled;
boolean LsoEnabled;
uint32 UdpEspEnabled;
uint32 AuthenticationAlgorithmsEnabled;
uint32 EncryptionAlgorithmsEnabled;
uint32 SaOffloadCapacityEnabled;
};
Members
The MSFT_NetAdapterIPsecOffloadV2SettingData class has these types of members:
Methods
The MSFT_NetAdapterIPsecOffloadV2SettingData class has these methods.
| Method | Description |
|---|---|
| Disable | Disable IPsec Task Offload v2 on the network adapter. |
| Enable | Enable IPsec Task Offload v2 on the network adapter. |
| Set | Set the IPsec Task Offload v2 properties on the network adapter. |
Properties
The MSFT_NetAdapterIPsecOffloadV2SettingData class has these properties.
-
AhEnabled
-
-
Data type: boolean
-
Access type: Read-only
AH enabled.
-
-
AhEspCombinedEnabled
-
-
Data type: boolean
-
Access type: Read-only
Both AH and ESP combined enabled.
-
-
AhEspCombinedSupported
-
-
Data type: boolean
-
Access type: Read-only
Supports both Ah and Esp.
-
-
AhSupported
-
-
Data type: boolean
-
Access type: Read-only
Supports Ah.
-
-
AuthenticationAlgorithmsEnabled
-
-
Data type: uint32
-
Access type: Read-only
Authentication Algorithms enabled.
-
-
AuthenticationAlgorithmsSupported
-
-
Data type: uint32
-
Access type: Read-only
Supports authentication algorithms.
-
-
Caption
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: MaxLen ( 64 )
A short textual description of the object. This property inherits from CIM_ManagedElement.
-
-
Description
-
-
Data type: string
-
Access type: Read-only
A textual description of the object. This property inherits from CIM_ManagedElement.
-
-
ElementName
-
-
Data type: string
-
Access type: Read-only
A user-friendly name for the object. This property enables each instance to define a display name in addition to its key properties, identity data, and description information. Be aware that the Name property of ManagedSystemElement is also defined as a display name. However, it is often subclassed to be a Key. The same property can convey both identity and a user-friendly name, without inconsistencies. Where Name exists and is not a Key (such as for instances of LogicalDevice), the same information can be present in both the Name and ElementName properties. This property inherits from CIM_ManagedElement.
-
-
Enabled
-
-
Data type: boolean
-
Access type: Read/write
Enabled.
-
-
EncryptionAlgorithmsEnabled
-
-
Data type: uint32
-
Access type: Read-only
Encryption algorithms enabled.
-
-
EncryptionAlgorithmsSupported
-
-
Data type: uint32
-
Access type: Read-only
Supports encryption algorithms.
-
-
EspEnabled
-
-
Data type: boolean
-
Access type: Read-only
ESP enabled.
-
-
EspSupported
-
-
Data type: boolean
-
Access type: Read-only
Supports Esp.
-
-
InstanceID
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Key
Within the scope of the instantiating Namespace, InstanceID opaquely and uniquely identifies an instance of this class. To ensure uniqueness within the NameSpace, the value of InstanceID should be constructed using the following "preferred" algorithm: OrgID:LocalID Where OrgID and LocalID are separated by a colon (:), and where OrgID must include a copyrighted, trademarked, or otherwise unique name that is owned by the business entity that is creating or defining the InstanceID or that is a registered ID assigned to the business entity by a recognized global authority. (This requirement is similar to the SchemaName_ClassName structure of Schema class names.) In addition, to ensure uniqueness, OrgID must not contain a colon (:). When using this algorithm, the first colon to appear in InstanceID must appear between OrgID and LocalID. LocalID is chosen by the business entity and should not be reused to identify different underlying (real-world) elements. If the above preferred algorithm is not used, the defining entity must assure that the resulting InstanceID is not reused across any InstanceIDs produced by this or other providers for the NameSpace of this instance. For DMTF-defined instances, the "preferred" algorithm must be used with the OrgID set to CIM.
This property inherits from CIM_SettingData.
-
-
InterfaceDescription
-
-
Data type: string
-
Access type: Read-only
Interface Description, also known as "ifDesc" or display name is a unique name assigned to the network adapter during installation. This name cannot be changed and is persisted as long as the network adapter is not uninstalled. This property inherits from MSFT_NetAdapterSettingData.
-
-
IPv4OptionsEnabled
-
-
Data type: boolean
-
Access type: Read-only
IPv4 options enabled.
-
-
IPv4OptionsSupported
-
-
Data type: boolean
-
Access type: Read-only
Supports IPv4 options.
-
-
IPv6Enabled
-
-
Data type: boolean
-
Access type: Read-only
IPv6 enabled.
-
-
IPv6NonIPsecExtensionHeadersEnabled
-
-
Data type: boolean
-
Access type: Read-only
IPv6 non-IP security extension headers enabled.
-
-
IPv6NonIPsecExtensionHeadersSupported
-
-
Data type: boolean
-
Access type: Read-only
Supports IPv6 non-IP security extension headers.
-
-
IPv6Supported
-
-
Data type: boolean
-
Access type: Read-only
Supports IPv6.
-
-
LsoEnabled
-
-
Data type: boolean
-
Access type: Read-only
LSO enabled.
-
-
LsoSupported
-
-
Data type: boolean
-
Access type: Read-only
Supports Lso.
-
-
Name
-
-
Data type: string
-
Access type: Read-only
Name, also known as Connection Name, "ifAlias", or InterfaceAlias, is a unique name assigned to the adapter during installation. The Name of the adapter can be changed by the administrator and is persisted across the boot or network adapter restart. This property inherits from MSFT_NetAdapterSettingData.
-
-
SaOffloadCapacityEnabled
-
-
Data type: uint32
-
Access type: Read-only
SA offload capacity enabled.
-
-
SaOffloadCapacitySupported
-
-
Data type: uint32
-
Access type: Read-only
The ammount of SA offload capacity supported.
-
-
Source
-
-
Data type: uint32
-
Access type: Read-only
The source of the setting data. This property inherits from MSFT_NetAdapterSettingData.
-
Unknown (0)
-
Other (1)
-
Device (2)
-
Persistent storage (3)
-
-
SystemName
-
-
Data type: string
-
Access type: Read-only
The scoping System\'s Name. This property inherits from MSFT_NetAdapterSettingData.
-
-
TransportEnabled
-
-
Data type: boolean
-
Access type: Read-only
Transport enabled.
-
-
TransportSupported
-
-
Data type: boolean
-
Access type: Read-only
Supports transport.
-
-
TunnelEnabled
-
-
Data type: boolean
-
Access type: Read-only
Tunnel enabled.
-
-
TunnelSupported
-
-
Data type: boolean
-
Access type: Read-only
Supports tunnel.
-
-
UdpEspEnabled
-
-
Data type: uint32
-
Access type: Read-only
UDP and ESP enabled.
-
-
UdpEspSupported
-
-
Data type: uint32
-
Access type: Read-only
Supports UDP and ESP.
-
Requirements
| Requirement | Value |
|---|---|
| Minimum supported client |
None supported |
| Minimum supported server |
Windows Server 2012 |
| Namespace |
Root\StandardCimv2 |
| MOF |
|
| DLL |
|