load command
The load command loads a file in a device-specific format. Digital-video and video-overlay devices recognize this command.
To send this command, call the mciSendString function with the lpszCommand parameter set as follows.
_stprintf_s(
lpszCommand,
TEXT("load %s %s %s"),
lpszDeviceID,
lpszFilePos,
lpszFlags
);
-
lpszDeviceID
-
Identifier of an MCI device. This identifier or alias is assigned when the device is opened.
-
lpszFilePos
-
Path and filename to load. For video-overlay devices, this can also include a target rectangle for the data. To specify a target rectangle, specify "at" followed by X1 Y1 X2 Y2, where X1 Y1 specify the upper left corner of the rectangle, and X2 Y2 specify the width and height. The rectangle is relative to the video buffer origin.
-
lpszFlags
-
Can be "wait", "notify", or both. For digital-video devices, "test" can also be specified. For more information about these flags, see The Wait, Notify, and Test Flags.
Returns zero if successful or an error otherwise.
The "vidboard" device sends a notification message when the loading is completed.
The following command loads a file into the "vidboard" device.
load vidboard c:\vid\fish.vid notify
Requirement | Value |
---|---|
Minimum supported client |
Windows 2000 Professional [desktop apps only] |
Minimum supported server |
Windows 2000 Server [desktop apps only] |