If you would like to enable tracing for UAG client side to trace end point detection components bit in case of any problem then here are the options you need to enable on UAG and IAG update 3:
Browse to \Program Files\Microsoft Forefront UAG\EndPoint Components\3.1.0Run trace.hta
Scroll to the bottom of the window. If it says ‘Logging is currently ON’ then click ‘Stop’
Add ticks to all the tickboxes (Error Warn, Info, Func & Noise) for these components:
· CompMgr_BASE
· Detector_BASE
· Security_CheckSite
· SoftToken
· TCPDump
· VistaUtils
· SSLVPN_BASE
· IPC_BASE
· LSP_BASE
· NSP_BASE
Scroll to the bottom of the window and click ‘Go’
Reproduce the problem
Click ‘Stop’ in trace.hta
Send the Forefront_UAG.bin file from c:\windows\debug\ to CSS for troubleshooting.