New-SCLogicalSwitchVirtualNetworkAdapter

Agrega un adaptador de red virtual (VNIC) a un conmutador lógico.

Syntax

New-SCLogicalSwitchVirtualNetworkAdapter
   -UplinkPortProfileSet <UplinkPortProfileSet>
   [-EthernetAddressType <EthernetAddressType>]
   [-IPv4AddressType <EthernetAddressType>]
   [-IPv6AddressType <EthernetAddressType>]
   [-VMNetwork <VMNetwork>]
   [-VMSubnet <VMSubnet>]
   [-PortClassification <PortClassification>]
   [-VLanEnabled <Boolean>]
   [-VLanID <UInt16>]
   [-IPv4AddressPool <StaticIPAddressPool>]
   [-IPv6AddressPool <StaticIPAddressPool>]
   [-InheritsAddressFromPhysicalNetworkAdapter <Boolean>]
   [-IsUsedForHostManagement <Boolean>]
   [-VMMServer <ServerConnection>]
   [-Name] <String>
   [[-Description] <String>]
   [-RunAsynchronously]
   [-PROTipID <Guid>]
   [-JobVariable <String>]
   [<CommonParameters>]

Description

El cmdlet New-SCLogicalSwitchVirtualNetworkAdapter agrega un adaptador de red virtual (VNIC) para el host al perfil de puerto de vínculo superior como parte de la definición del conmutador lógico.

Ejemplos

Ejemplo 1: Crea un nuevo adaptador de red virtual de conmutador lógico

PS C:\> $UPPSet = Get-SCUplinkPortProfileSet -Name "R1Uplink"
PS C:\> $VmNetwork = Get-SCVMNetwork -Name "MgmtNet"
PS C:\> New-SCLogicalSwitchVirtualNetworkAdapter -Name "LogSw01_Storage" -UplinkPortProfileSet $uppSetVar -RunAsynchronously -VMNetwork $vmNetwork -VLanEnabled $true -VLanID 2162 -IsUsedForHostManagement $false -IPv4AddressType "Dynamic" -IPv6AddressType "Dynamic"

El primer comando obtiene un perfil de puerto de vínculo superior establecido mediante el cmdlet Get-SCUplinkPortProfileSet y, a continuación, lo almacena en la variable $UPPSet.

El segundo comando obtiene la red de máquina virtual denominada MgmtNet mediante el cmdlet Get-SCVMNetwork y, a continuación, la almacena en la variable $VmNetwork.

El comando final crea un adaptador de red virtual de conmutador lógico que se implementa en el host junto con el conmutador lógico.

Parámetros

-Description

Especifica una descripción para el adaptador de red virtual.

Type:String
Position:1
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-EthernetAddressType

Especifica un tipo de dirección Ethernet. Los valores permitidos para este parámetro son los siguientes:

  • Dinámica
  • estática
Type:EthernetAddressType
Accepted values:Dynamic, Static
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-InheritsAddressFromPhysicalNetworkAdapter

Indica si el adaptador de red hereda su dirección de un adaptador de red físico.

Type:Boolean
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-IPv4AddressPool

Especifica un grupo de direcciones estáticas que contiene direcciones IPv4.

Type:StaticIPAddressPool
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-IPv4AddressType

Especifica un tipo de dirección IPv4. Los valores permitidos para este parámetro son los siguientes:

  • Dinámica
  • estática
Type:EthernetAddressType
Accepted values:Dynamic, Static
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-IPv6AddressPool

Especifica un grupo de direcciones estáticas que contiene direcciones IPv6.

Type:StaticIPAddressPool
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-IPv6AddressType

Especifica un tipo de dirección IPv6. Los valores permitidos para este parámetro son los siguientes:

  • Dinámica
  • estática
Type:EthernetAddressType
Accepted values:Dynamic, Static
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-IsUsedForHostManagement

Indica si el adaptador de red virtual se usa para la administración del host.

Type:Boolean
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-JobVariable

Especifica que se realiza un seguimiento del progreso del trabajo y que se almacena en la variable cuyo nombre indica este parámetro.

Type:String
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-Name

Especifica el nombre del adaptador de red.

Type:String
Position:0
Default value:None
Required:True
Accept pipeline input:False
Accept wildcard characters:False

-PortClassification

Especifica la clasificación de puerto del conmutador al que se conecta el adaptador de red virtual.

Type:PortClassification
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-PROTipID

Especifica el identificador de la sugerencia rendimiento y optimización de recursos (sugerencia PRO) que desencadenó esta acción. Este parámetro le permite auditar sugerencias PRO.

Type:Guid
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-RunAsynchronously

Indica que el trabajo se ejecuta de forma asincrónica para que el control vuelva al shell de comandos inmediatamente.

Type:SwitchParameter
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-UplinkPortProfileSet

Especifica un objeto de conjunto de perfiles de puerto de vínculo superior.

Para obtener un objeto de conjunto de perfiles de puerto de vínculo superior, use el cmdlet Get-SCUplinkPortProfileSet .

Type:UplinkPortProfileSet
Position:Named
Default value:None
Required:True
Accept pipeline input:True
Accept wildcard characters:False

-VLanEnabled

Indica si se va a habilitar una LAN virtual (VLAN) para que la usen las máquinas virtuales en un host de Hyper-V o Citrix XenServer.

  • Formato de ejemplo para una sola VLAN: -VLANEnabled -VLANMode "Access" -VLANID 35
  • Formato de ejemplo para varias VLAN: -VLANEnabled -VLANMode "Trunk" -VLANTrunkID 1,2,100,200,1124
Type:Boolean
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-VLanID

Asigna un identificador numérico en el intervalo 1-4094 a un adaptador de red virtual en una máquina virtual o a un adaptador de red físico en un host de máquina virtual.

Configure un VLanID en un host de Hyper-V, VMware ESX o Citrix XenServer en un adaptador de red físico enlazado externamente cuando el modo VLan sea Access.

Configure un VLanID en un adaptador de red virtual de una máquina virtual enlazada a un adaptador de red físico en el host o enlazado a una red virtual interna en el host.

Formato de ejemplo: -VLanEnabled -VLanMode "Access" -VLANID 35

Type:UInt16
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-VMMServer

Especifica un objeto de servidor VMM.

Type:ServerConnection
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-VMNetwork

Especifica un objeto de red de máquina virtual.

Para obtener un objeto de red de máquina virtual, use el cmdlet Get-SCVMNetwork .

Type:VMNetwork
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-VMSubnet

Especifica un objeto de subred de máquina virtual.

Para obtener un objeto VMSubnet , use el cmdlet Get-SCVMSubnet .

Type:VMSubnet
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False