Implement the device

Devices that connect to IoT Central should follow the IoT Plug and Play conventions. One of these conventions is that a device should send the model ID of the device model it implements when it connects. The model ID enables the IoT Central application to assign the device to the correct device template.

An IoT Central device template includes a model that specifies the behaviors a device of that type should implement. Behaviors include telemetry, properties, and commands.

Each model has a unique digital twin model identifier (DTMI), such as dtmi:com:example:Thermostat;1. When a device connects to IoT Central, it sends the DTMI of the model it implements. IoT Central can then assign the correct device template to the device.

IoT Plug and Play defines a set of conventions that a device should follow when it implements a Digital Twin Definition Language (DTDL) model.

The Azure IoT device SDKs include support for the IoT Plug and Play conventions.

Device model

For IoT Central, a device model is defined by using the DTDL v2 modeling language. This language lets you define:

  • The telemetry the device sends. The definition includes the name and data type of the telemetry. For example, a device sends temperature telemetry as a double.
  • The properties the device reports to IoT Central. A property definition includes its name and data type. For example, a device reports the state of a valve as a Boolean.
  • The properties the device can receive from IoT Central. Optionally, you can mark a property as writable. For example, IoT Central sends a target temperature as a double to a device.
  • The commands a device responds to. The definition includes the name of the command, and the names and data types of any parameters. For example, a device responds to a reboot command that specifies how many seconds to wait before rebooting.

Note

IoT Central defines some extensions to the DTDL v2 language. To learn more, see IoT Central extension.

A DTDL model can be a no-component or a multi-component model:

  • No-component model: A simple model doesn't use embedded or cascaded components. All the telemetry, properties, and commands are defined a single root component. For an example, see the Thermostat model.
  • Multi-component model. A more complex model that includes two or more components. These components include a single root component, and one or more nested components. For an example, see the Temperature Controller model.

Tip

You can import and export a complete device model or individual interface from an IoT Central device template as a DTDL v2 file.

To learn more about device models, see the IoT Plug and Play modeling guide

Conventions

A device should follow the IoT Plug and Play conventions when it exchanges data with IoT Central. The conventions include:

  • Send the DTMI when it connects to IoT Central.
  • Send correctly formatted JSON payloads and metadata to IoT Central.
  • Correctly respond to writable properties and commands from IoT Central.
  • Follow the naming conventions for component commands.

Note

Currently, IoT Central does not fully support the DTDL Array and Geospatial data types.

To learn more about the IoT Plug and Play conventions, see IoT Plug and Play conventions.

To learn more about the format of the JSON messages that a device exchanges with IoT Central, see Telemetry, property, and command payloads.

Device SDKs

To implement the code that runs on your device, you should use one of the Azure IoT device SDKs. Actions your code should implement include:

  • Register the device with DPS and use the information from DPS to connect to the internal IoT hub in your IoT Central application.
  • Announce the DTMI of the model the device implements.
  • Send telemetry in the format that the device model specifies. To determine how to use the telemetry for visualizations and analysis, IoT Central uses the model in the device template.
  • Synchronize property values between the device and IoT Central. The model specifies the property names and data types so that IoT Central can display the information.
  • Implement command handlers for the commands specified in the model. The model specifies the command names and parameters that the device should use.

For more information about the role of device templates, see What are device templates?.

The following table summarizes how Azure IoT Central device features map on to IoT Hub features:

Azure IoT Central Azure IoT Hub
Telemetry Device-to-cloud messaging
Offline commands Cloud-to-device messaging
Property Device twin reported properties
Property (writable) Device twin desired and reported properties
Command Direct methods

Communication protocols

Communication protocols that a device can use to connect to IoT Central include MQTT, AMQP, and HTTPS. Internally, IoT Central uses an IoT hub to enable device connectivity. For more information about the communication protocols that IoT Hub supports for device connectivity, see Choose a communication protocol.

If your device can't use any of the supported protocols, use Azure IoT Edge to do protocol conversion. IoT Edge supports other intelligence-on-the-edge scenarios to offload processing from the Azure IoT Central application.

Telemetry timestamps

By default, IoT Central uses the message enqueued time when it displays telemetry on dashboards and charts. Message enqueued time is set internally when IoT Central receives the message from the device.

A device can set the iothub-creation-time-utc property when it creates a message to send to IoT Central. If this property is present, IoT Central uses it when it displays telemetry on dashboards and charts.

You can export both the enqueued time and the iothub-creation-time-utc property when you export telemetry from your IoT Central application.

To learn more about message properties, see System Properties of device-to-cloud IoT Hub messages.

Best practices

These recommendations show how to implement devices to take advantage of the built-in high availability, disaster recovery, and automatic scaling in IoT Central.

Device provisioning

As the number of IoT hubs in your application changes, a device might need to connect to a different hub.

Before a device connects to IoT Central, it must be registered and provisioned in the underlying services. When you add a device to an IoT Central application, IoT Central adds an entry to a DPS enrollment group. Information from the enrollment group such as the ID scope, device ID, and keys is surfaced in the IoT Central UI.

When a device first connects to your IoT Central application, DPS provisions the device in one of the enrollments group's linked IoT hubs. The device is then associated with that IoT hub. DPS uses an allocation policy to load balance the provisioning across the IoT hubs in the application. This process makes sure each IoT hub has a similar number of provisioned devices.

To learn more about registration and provisioning in IoT Central, see IoT Central device connectivity guide.

Handle connection failures

When IoT Central automatically scales or handles a disaster recovery scenario, it might update its underlying IoT hubs. To maintain connectivity, your device code should handle specific connection errors by establishing a connection to a new IoT Hub endpoint.

If the device gets any of the following errors when it connects, it should reprovision the device with DPS to get a new connection string. These errors mean the connection string is no longer valid:

  • Unreachable IoT Hub endpoint.
  • Expired security token.
  • Device disabled in IoT Hub.

If the device gets any of the following errors when it connects, it should use a back-off strategy to retry the connection. These errors mean the connection string is still valid, but transient conditions are stopping the device from connecting:

  • Operator blocked device.
  • Internal error 500 from the service.

To learn more about device error codes, see Troubleshooting device connections.

To learn more about implementing automatic reconnections, see Manage device reconnections to create resilient applications.

Currently, IoT Edge devices can't move between IoT hubs.

Test failover capabilities

The Azure CLI lets you test the failover capabilities of your device code. The CLI command works by temporarily switching a device registration to a different internal IoT hub. To verify the device failover worked, check that the device still sends telemetry and responds to commands.

To run the failover test for your device, run the following command:

az iot central device manual-failover \
    --app-id {Application ID of your IoT Central application} \
    --device-id {Device ID of the device you're testing} \
    --ttl-minutes {How to wait before moving the device back to it's original IoT hub}

Tip

To find the Application ID, navigate to Application > Management in your IoT Central application.

If the command succeeds, you see output that looks like the following example:

Command group 'iot central device' is in preview and under development. Reference and support levels: https://aka.ms/CLI_refstatus
{
  "hubIdentifier": "6bd4...bafa",
  "message": "Success! This device is now being failed over. You can check your device'’'s status using 'iot central device registration-info' command. The device will revert to its original hub at Tue, 18 May 2021 11:03:45 GMT. You can choose to failback earlier using device-manual-failback command. Learn more: https://aka.ms/iotc-device-test"
}

To learn more about the CLI command, see az iot central device manual-failover.

You can now check that telemetry from the device still reaches your IoT Central application.

Tip

To see sample device code that handles failovers in various programing languages, see IoT Central high availability clients.

Next steps