संपादित करें

इसके माध्यम से साझा किया गया


Microsoft Entra Connect Sync: Make a change to the default configuration

The purpose of this article is to walk you through how to make changes to the default configuration in Microsoft Entra Connect Sync. It provides steps for some common scenarios. With this knowledge, you should be able to make simple changes to your own configuration based on your own business rules.

Warning

If you make changes to the default out-of-box sync rules then these changes will be overwritten the next time Microsoft Entra Connect is updated, resulting in unexpected and likely unwanted synchronization results.

The default out-of-box sync rules have a thumbprint. If you make a change to these rules, the thumbprint is no longer matching. You might have problems in the future when you try to apply a new release of Microsoft Entra Connect. Only make changes the way it is described in this article.

Synchronization Rules Editor

The Synchronization Rules Editor is used to see and change the default configuration. You can find it on the Start menu under the Microsoft Entra Connect group.
Start menu with Sync Rule Editor

When you open the editor, you see the default out-of-box rules.

Sync Rule Editor

Using the drop-downs at the top of the editor, you can quickly find a specific rule. For example, if you want to see the rules where the attribute proxyAddresses is included, you can change the drop-downs to the following:
SRE filtering
To reset filtering and load a fresh configuration, press F5 on the keyboard.

On the upper right is the Add new rule button. You use this button to create your own custom rule.

At the bottom are buttons for acting on a selected sync rule. Edit and Delete do what you expect them to. Export produces a PowerShell script for re-creating the sync rule. With this procedure, you can move a sync rule from one server to another.

Create your first custom rule

The most common changes are to the attribute flows. The data in your source directory might not be the same as in Microsoft Entra ID. In the example in this section, make sure the given name of a user is always in proper case.

Disable the scheduler

The scheduler runs every 30 minutes by default. Make sure it is not starting while you are making changes and troubleshooting your new rules. To temporarily disable the scheduler, start PowerShell and run Set-ADSyncScheduler -SyncCycleEnabled $false.

Disable the scheduler

Create the rule

  1. Click Add new rule.
  2. On the Description page, enter the following:
    Inbound rule filtering
    • Name: Give the rule a descriptive name.
    • Description: Give some clarification so someone else can understand what the rule is for.
    • Connected System: This is the system in which the object can be found. In this case, select Active Directory Connector.
    • Connected System/Metaverse Object Type: Select User and Person, respectively.
    • Link Type: Change this value to Join.
    • Precedence: Provide a value that is unique in the system. A lower numeric value indicates higher precedence.
    • Tag: Leave this empty. Only out-of-box rules from Microsoft should have this box populated with a value.
  3. On the Scoping filter page, enter givenName ISNOTNULL.
    Inbound rule scoping filter
    This section is used to define to which objects the rule should apply. If it's left empty, the rule would apply to all user objects. However, that would include conference rooms, service accounts, and other non-people user objects.
  4. On the Join rules page, leave the field empty.
  5. On the Transformations page, change FlowType to Expression. For Target Attribute, select givenName. And for Source, enter PCase([givenName]). Inbound rule transformations
    The sync engine is case-sensitive for both the function name and the name of the attribute. If you type something wrong, you see a warning when you add the rule. You can save and continue, but you need to reopen and correct the rule.
  6. Click Add to save the rule.

Your new custom rule should be visible with the other sync rules in the system.

Verify the change

With this new change, you want to make sure it is working as expected and is not throwing any errors. Depending on the number of objects you have, there are two ways to do this step:

  • Run a full sync on all objects.
  • Run a preview and full sync on a single object.

Open the Synchronization Service from the Start menu. The steps in this section are all in this tool.

Full sync on all objects

  1. Select Connectors at the top. Identify the connector that you changed in the previous section (in this case, Active Directory Domain Services), and select it.
  2. For Actions, select Run.
  3. Select Full Synchronization, and then select OK. Full sync
    The objects are now updated in the metaverse. Verify your changes by looking at the object in the metaverse.

Preview and full sync on a single object

  1. Select Connectors at the top. Identify the connector that you changed in the previous section (in this case, Active Directory Domain Services), and select it.
  2. Select Search Connector Space.
  3. Use Scope to find an object that you want to use to test the change. Select the object and click Preview.
  4. On the new screen, select Commit Preview.
    Commit preview
    The change is now committed to the metaverse.

View the object in the metaverse

  1. Pick a few sample objects to make sure that the value is expected and that the rule applied.
  2. Select Metaverse Search from the top. Add any filter that you need to find the relevant objects.
  3. From the search result, open an object. Look at the attribute values, and also verify in the Sync Rules column that the rule applied as expected.
    Metaverse search

Enable the scheduler

If everything is as expected, you can enable the scheduler again. From PowerShell, run Set-ADSyncScheduler -SyncCycleEnabled $true.

Other common attribute flow changes

The previous section described how to make changes to an attribute flow. In this section, some additional examples are provided. The steps for how to create the sync rule is abbreviated, but you can find the full steps in the previous section.

Use an attribute other than the default

In this Fabrikam scenario, there is a forest where the local alphabet is used for given name, surname, and display name. The Latin character representation of these attributes can be found in the extension attributes. For building a global address list in Microsoft Entra ID and Microsoft 365, the organization wants to use these attributes instead.

With a default configuration, an object from the local forest looks like this:
Attribute flow 1

To create a rule with other attribute flows, do the following:

  1. Open the Synchronization Rules Editor from the Start menu.
  2. With Inbound still selected to the left, click the Add new rule button.
  3. Give the rule a name and description. Select the on-premises Active Directory instance and the relevant object types. In Link Type, select Join. For Precedence, pick a number that is not used by another rule. The out-of-box rules start with 100, so the value 50 can be used in this example. Attribute flow 2
  4. Leave Scoping filter empty. (That is, it should apply to all user objects in the forest.)
  5. Leave Join rules empty. (That is, let the out-of-box rule handle any joins.)
  6. In Transformations, create the following flows:
    Attribute flow 3
  7. Click Add to save the rule.
  8. Go to Synchronization Service Manager. On Connectors, select the connector where you added the rule. Select Run, and then select Full Synchronization. A full synchronization recalculates all objects by using the current rules.

This is the result for the same object with this custom rule:
Attribute flow 4

Length of attributes

String attributes are indexable by default, and the maximum length is 448 characters. If you are working with string attributes that might contain more, make sure to include the following in the attribute flow:
attributeName <- Left([attributeName],448).

Changing the userPrincipalSuffix

The userPrincipalName attribute in Active Directory is not always known by the users and might not be suitable as the sign-in ID. With the Microsoft Entra Connect sync installation wizard, you can choose a different attribute--for example, mail. But in some cases, the attribute must be calculated.

For example, the company Contoso has two Microsoft Entra directories, one for production and one for testing. They want the users in their test tenant to use another suffix in the sign-in ID:
Word([userPrincipalName],1,"@") & "@contosotest.com".

In this expression, take everything left of the first @-sign (Word) and concatenate with a fixed string.

Convert a multi-value attribute to single value

Some attributes in Active Directory are multi-valued in the schema, even though they look single-valued in Active Directory Users and Computers. An example is the description attribute:
description <- IIF(IsNullOrEmpty([description]),NULL,Left(Trim(Item([description],1)),448)).

In this expression, if the attribute has a value, take the first item (Item) in the attribute, remove leading and trailing spaces (Trim), and then keep the first 448 characters (Left) in the string.

Do not flow an attribute

For background on the scenario for this section, see Control the attribute flow process.

There are two ways to not flow an attribute. The first is by using the installation wizard to remove selected attributes. This option works if you have never synchronized the attribute before. However, if you have started to synchronize this attribute and later remove it with this feature, the sync engine stops managing the attribute and the existing values are left in Microsoft Entra ID.

If you want to remove the value of an attribute and make sure it does not flow in the future, you need create a custom rule.

In this Fabrikam scenario, we have realized that some of the attributes we synchronize to the cloud should not be there. We want to make sure these attributes are removed from Microsoft Entra ID.
Bad extension attributes

  1. Create a new inbound synchronization rule and populate the description. Descriptions
  2. Create attribute flows with Expression for FlowType and with AuthoritativeNull for Source. The literal AuthoritativeNull indicates that the value should be empty in the metaverse, even if a lower-precedence sync rule tries to populate the value. Transformation for extension attributes
  3. Save the sync rule. Start the Synchronization Service, find the connector, select Run, and then select Full Synchronization. This step recalculates all attribute flows.
  4. Verify that the intended changes are about to be exported by searching the Connector Space. Staged delete

Create rules with PowerShell

Using the sync rule editor works fine when you only have a few changes to make. If you need to make many changes, PowerShell might be a better option. Some advanced features are only available with PowerShell.

Get the PowerShell script for an out-of-box rule

To see the PowerShell script that created an out-of-box rule, select the rule in the sync rules editor and click Export. This action gives you the PowerShell script that created the rule.

Advanced precedence

The out-of-box sync rules start with a precedence value of 100. If you have many forests and you need to make many custom changes, then 99 sync rules might not be enough.

You can instruct the sync engine that you want additional rules inserted before the out-of-box rules. To get this behavior, follow these steps:

  1. Mark the first out-of-box sync rule (In from AD-User Join) in the sync rules editor and select Export. Copy the SR Identifier value.
    PowerShell before change
  2. Create the new sync rule. You can use the sync rules editor to create it. Export the rule to a PowerShell script.
  3. In the property PrecedenceBefore, insert the Identifier value from the out-of-box rule. Set the Precedence to 0. Make sure the Identifier attribute is unique and that you are not reusing a GUID from another rule. Also make sure that the ImmutableTag property is not set. This property should be set only for an out-of-box rule.
  4. Save the PowerShell script and run it. The result is that your custom rule is assigned the precedence value of 100 and all other out-of-box rules are incremented.
    PowerShell after change

You can have many custom sync rules by using the same PrecedenceBefore value when needed.

Enable synchronization of UserType

Microsoft Entra Connect supports synchronization of the UserType attribute for User objects in version 1.1.524.0 and later. More specifically, the following changes have been introduced:

  • The schema of the object type User in the Microsoft Entra Connector is extended to include the UserType attribute, which is of the type string and is single-valued.
  • The schema of the object type Person in the metaverse is extended to include the UserType attribute, which is of the type string and is single-valued.

By default, the UserType attribute is not enabled for synchronization because there is no corresponding UserType attribute in on-premises Active Directory. You must manually enable synchronization. Before doing this, you must take note of the following behavior enforced by Microsoft Entra ID:

  • Microsoft Entra-only accepts two values for the UserType attribute: Member and Guest.
  • If the UserType attribute is not enabled for synchronization in Microsoft Entra Connect, Microsoft Entra users created through directory synchronization would have the UserType attribute set to Member.
  • Prior to version 1.5.30.0, Microsoft Entra ID did not permit the UserType attribute on existing Microsoft Entra users to be changed by Microsoft Entra Connect. In older versions, it could only be set during the creation of the Microsoft Entra users and changed via PowerShell.

Before enabling synchronization of the UserType attribute, you must first decide how the attribute is derived from on-premises Active Directory. The following are the most common approaches:

  • Designate an unused on-premises AD attribute (such as extensionAttribute1) to be used as the source attribute. The designated on-premises AD attribute should be of the type string, be single-valued, and contain the value Member or Guest.

    If you choose this approach, you must ensure that the designated attribute is populated with the correct value for all existing user objects in on-premises Active Directory that are synchronized to Microsoft Entra ID before enabling synchronization of the UserType attribute.

  • Alternatively, you can derive the value for the UserType attribute from other properties. For example, you want to synchronize all users as Guest if their on-premises AD userPrincipalName attribute ends with domain part @partners.fabrikam123.org.

    As mentioned previously, older versions of Microsoft Entra Connect do not permit the UserType attribute on existing Microsoft Entra users to be changed by Microsoft Entra Connect. Therefore, you must ensure that the logic you have decided is consistent with how the UserType attribute is already configured for all existing Microsoft Entra users in your tenant.

The steps to enable synchronization of the UserType attribute can be summarized as:

  1. Disable the sync scheduler and verify there is no synchronization in progress.
  2. Add the source attribute to the on-premises AD Connector schema.
  3. Add the UserType to the Microsoft Entra Connector schema.
  4. Create an inbound synchronization rule to flow the attribute value from on-premises Active Directory.
  5. Create an outbound synchronization rule to flow the attribute value to Microsoft Entra ID.
  6. Run a full synchronization cycle.
  7. Enable the sync scheduler.

Note

The rest of this section covers these steps. They are described in the context of a Microsoft Entra deployment with single-forest topology and without custom synchronization rules. If you have multi-forest topology, custom synchronization rules configured, or have a staging server, you need to adjust the steps accordingly.

Step 1: Disable the sync scheduler and verify there is no synchronization in progress

To avoid exporting unintended changes to Microsoft Entra ID, ensure that no synchronization takes place while you are in the middle of updating synchronization rules. To disable the built-in sync scheduler:

  1. Start a PowerShell session on the Microsoft Entra Connect server.
  2. Disable scheduled synchronization by running the cmdlet Set-ADSyncScheduler -SyncCycleEnabled $false.
  3. Open the Synchronization Service Manager by going to Start > Synchronization Service.
  4. Go to the Operations tab and confirm there is no operation with a status of in progress.

Step 2: Add the source attribute to the on-premises AD Connector schema

Not all Microsoft Entra attributes are imported into the on-premises AD Connector Space. To add the source attribute to the list of the imported attributes:

  1. Go to the Connectors tab in the Synchronization Service Manager.
  2. Right-click the on-premises AD Connector and select Properties.
  3. In the pop-up dialog box, go to the Select Attributes tab.
  4. Make sure the source attribute is checked in the attribute list.
  5. Click OK to save. Add source attribute to on-premises AD Connector schema

Step 3: Add the UserType attribute to the Microsoft Entra Connector schema

By default, the UserType attribute is not imported into the Microsoft Entra Connect Space. To add the UserType attribute to the list of imported attributes:

  1. Go to the Connectors tab in the Synchronization Service Manager.
  2. Right-click the Microsoft Entra Connector and select Properties.
  3. In the pop-up dialog box, go to the Select Attributes tab.
  4. Make sure the UserType attribute is checked in the attribute list.
  5. Click OK to save.

Add source attribute to Microsoft Entra Connector schema

Step 4: Create an inbound synchronization rule to flow the attribute value from on-premises Active Directory

The inbound synchronization rule permits the attribute value to flow from the source attribute from on-premises Active Directory to the metaverse:

  1. Open the Synchronization Rules Editor by going to Start > Synchronization Rules Editor.

  2. Set the search filter Direction to be Inbound.

  3. Click the Add new rule button to create a new inbound rule.

  4. Under the Description tab, provide the following configuration:

    Attribute Value Details
    Name Provide a name For example, In from AD – User UserType
    Description Provide a description
    Connected System Pick the on-premises AD connector
    Connected System Object Type User
    Metaverse Object Type Person
    Link Type Join
    Precedence Choose a number between 1–99 1–99 is reserved for custom sync rules. Do not pick a value that is used by another synchronization rule.
  5. Go to the Scoping filter tab and add a single scoping filter group with the following clause:

    Attribute Operator Value
    adminDescription NOTSTARTWITH User_

    The scoping filter determines to which on-premises AD objects this inbound synchronization rule is applied. In this example, we use the same scoping filter used in the In from AD – User Common out-of-box synchronization rule, which prevents the synchronization rule from being applied to User objects created through the Microsoft Entra user writeback feature. You might need to tweak the scoping filter according to your Microsoft Entra Connect deployment.

  6. Go to the Transformation tab and implement the desired transformation rule. For example, if you have designated an unused on-premises AD attribute (such as extensionAttribute1) as the source attribute for the UserType, you can implement a direct attribute flow:

    Flow type Target attribute Source Apply once Merge type
    Direct UserType extensionAttribute1 Unchecked Update

    In another example, you want to derive the value for the UserType attribute from other properties. For example, you want to synchronize all users as Guest if their on-premises AD userPrincipalName attribute ends with domain part @partners.fabrikam123.org. You can implement an expression like this:

    Flow type Target attribute Source Apply once Merge type
    Expression UserType IIF(IsPresent([userPrincipalName]),IIF(CBool(InStr(LCase([userPrincipalName]),"@partners.fabrikam123.org")=0),"Member","Guest"),Error("UserPrincipalName is not present to determine UserType")) Unchecked Update
  7. Click Add to create the inbound rule.

Create inbound synchronization rule

Step 5: Create an outbound synchronization rule to flow the attribute value to Microsoft Entra ID

The outbound synchronization rule permits the attribute value to flow from the metaverse to the UserType attribute in Microsoft Entra ID:

  1. Go to the Synchronization Rules Editor.

  2. Set the search filter Direction to be Outbound.

  3. Click the Add new rule button.

  4. Under the Description tab, provide the following configuration:

    Attribute Value Details
    Name Provide a name For example, Out to Microsoft Entra ID – User UserType
    Description Provide a description
    Connected System Select the Microsoft Entra connector
    Connected System Object Type User
    Metaverse Object Type Person
    Link Type Join
    Precedence Choose a number between 1–99 1–99 is reserved for custom sync rules. Do not pick a value that is used by another synchronization rule.
  5. Go to the Scoping filter tab and add a single scoping filter group with two clauses:

    Attribute Operator Value
    sourceObjectType EQUAL User
    cloudMastered NOTEQUAL True

    The scoping filter determines to which Microsoft Entra objects this outbound synchronization rule is applied. In this example, we use the same scoping filter from the Out to AD – User Identity out-of-box synchronization rule. It prevents the synchronization rule from being applied to User objects that are not synchronized from on-premises Active Directory. You might need to tweak the scoping filter according to your Microsoft Entra Connect deployment.

  6. Go to the Transformation tab and implement the following transformation rule:

    Flow type Target attribute Source Apply once Merge type
    Direct UserType UserType Unchecked Update
  7. Click Add to create the outbound rule.

Create outbound synchronization rule

Step 6: Run a full synchronization cycle

In general, a full synchronization cycle is required because we have added new attributes to both the Active Directory and Microsoft Entra Connector schemas, and introduced custom synchronization rules. You want to verify the changes before exporting them to Microsoft Entra ID.

You can use the following steps to verify the changes while manually running the steps that make up a full synchronization cycle.

  1. Run a Full import on the on-premises AD Connector:

    1. Go to the Connectors tab in the Synchronization Service Manager.

    2. Right-click the on-premises AD Connector and select Run.

    3. In the pop-up dialog box, select Full Import and then click OK.

    4. Wait for the operation to finish.

      Note

      You can skip a full import on the on-premises AD Connector if the source attribute is already included in the list of imported attributes. In other words, you did not have to make any changes during Step 2: Add the source attribute to the on-premises AD Connector schema.

  2. Run a Full import on the Microsoft Entra Connector:

    1. Right-click the Microsoft Entra Connector and select Run.
    2. In the pop-up dialog box, select Full Import and then click OK.
    3. Wait for the operation to finish.
  3. Verify the synchronization rule changes on an existing User object:

    The source attribute from on-premises Active Directory and the UserType from Microsoft Entra ID have been imported into their respective Connector Spaces. Before proceeding with a full synchronization, do a Preview on an existing User object in the on-premises AD Connector Space. The object you chose should have the source attribute populated.

    A successful Preview with the UserType populated in the metaverse is a good indicator that you have configured the synchronization rules correctly. For information about how to do a Preview, refer to the section Verify the change.

  4. Run a Full Synchronization on the on-premises AD Connector:

    1. Right-click the on-premises AD Connector and select Run.
    2. In the pop-up dialog box, select Full Synchronization and then click OK.
    3. Wait for the operation to finish.
  5. Verify Pending Exports to Microsoft Entra ID:

    1. Right-click the Microsoft Entra Connector and select Search Connector Space.

    2. In the Search Connector Space pop-up dialog box:

      • Set Scope to Pending Export.
      • Select all three check boxes: Add, Modify, and Delete.
      • Click the Search button to get the list of objects with changes to be exported. To examine the changes for a given object, double-click the object.
      • Verify that the changes are expected.
  6. Run Export on the Microsoft Entra Connector:

    1. Right-click the Microsoft Entra Connector and select Run.
    2. In the Run Connector pop-up dialog box, select Export and then click OK.
    3. Wait for the export to Microsoft Entra ID to finish.

Note

These steps do not include the full synchronization and export steps on the Microsoft Entra Connector. These steps are not required because the attribute values are flowing from on-premises Active Directory to Microsoft Entra-only.

Step 7: Re-enable the sync scheduler

Re-enable the built-in sync scheduler:

  1. Start a PowerShell session.
  2. Re-enable scheduled synchronization by running the cmdlet Set-ADSyncScheduler -SyncCycleEnabled $true.

Next steps

Overview topics