Condividi tramite


IDTSRuntimeConnection100.ConnectionManager Proprietà

Definizione

public:
 property Microsoft::SqlServer::Dts::Runtime::Wrapper::Sql2012::IDTSConnectionManager100 ^ ConnectionManager { Microsoft::SqlServer::Dts::Runtime::Wrapper::Sql2012::IDTSConnectionManager100 ^ get(); void set(Microsoft::SqlServer::Dts::Runtime::Wrapper::Sql2012::IDTSConnectionManager100 ^ value); };
[System.Runtime.InteropServices.DispId(102)]
public Microsoft.SqlServer.Dts.Runtime.Wrapper.Sql2012.IDTSConnectionManager100 ConnectionManager { [System.Runtime.InteropServices.DispId(102)] get; [System.Runtime.InteropServices.DispId(102)] set; }
[<System.Runtime.InteropServices.DispId(102)>]
[<get: System.Runtime.InteropServices.DispId(102)>]
[<set: System.Runtime.InteropServices.DispId(102)>]
member this.ConnectionManager : Microsoft.SqlServer.Dts.Runtime.Wrapper.Sql2012.IDTSConnectionManager100 with get, set
Public Property ConnectionManager As IDTSConnectionManager100

Valore della proprietà

IDTSConnectionManager100 del componente.

Attributi

Esempio

' TODO: Replace the path to the package with a valid path.  
Dim package As String = "c:\Package.dtsx"   

' Create the application and load the package.  
Dim a As Application = New Application   
Dim p As Package = a.LoadPackage(package, Nothing)   

' Walk the Executables collection looking for data flow tasks.  
For Each e As Executable In p.Executables   
 Dim mp As MainPipe = CType(CType(e, TaskHost).InnerObject, MainPipe)   
 If Not (e Is Nothing) Then   
   ' Walk the components.  
   For Each md As IDTSComponentMetaData100 In mp.ComponentMetaDataCollection   
     ' Walk the RuntimeConnectionCollection.  
     For Each rc As IDTSRuntimeConnection100 In md.RuntimeConnectionCollection   
       ' Check to see whether the package's connections collection    
       '  contains the Connectionmanager stored in the RuntimeConnection.  
       If p.Connections.Contains(rc.ConnectionManagerID) Then   
         rc.ConnectionManager = DtsConvert.ToConnectionManager100(p.Connections(rc.ConnectionManagerID))   
       Else   
         Console.WriteLine("The ConnectionManager " + rc.ConnectionManagerID + " was not found in the Package's Connections collection.")   
       End If   
     Next   
   Next   
 End If   
Next  
// TODO: Replace the path to the package with a valid path.  
string package = @"c:\Package.dtsx";  

// Create the application and load the package.  
Application a = new Application();  
Package p = a.LoadPackage( package , null );  

// Walk the Executables collection looking for data flow tasks.  
foreach (Executable e in p.Executables)  
{  
    MainPipe mp = ((TaskHost)e).InnerObject as MainPipe;  
    if( e != null )  
    {  
        // Walk the components.  
        foreach( IDTSComponentMetaData100 md in mp.ComponentMetaDataCollection )  
        {  
            // Walk the RuntimeConnectionCollection.  
            foreach( IDTSRuntimeConnection100 rc in md.RuntimeConnectionCollection )  
            {  
                // Check to see if the package's connections collection contains the   
                // Connectionmanager stored in the RuntimeConnection.  
                if (p.Connections.Contains(rc.ConnectionManagerID))  
                    rc.ConnectionManager = DtsConvert.ToConnectionManager100(p.Connections[rc.ConnectionManagerID]);  
                else  
                    Console.WriteLine("The ConnectionManager " + rc.ConnectionManagerID + " was not found in the Package's Connections collection.");  
            }  
        }  
    }  
}  

Commenti

La proprietà ConnectionManager contiene o imposta un riferimento all'istanza effettiva dell'oggetto IDTSConnectionManager100 contenuto nel pacchetto. In fase di esecuzione, questo riferimento viene impostato automaticamente dal motore di runtime SSIS usando la ConnectionManagerID proprietà per individuare la connessione nel pacchetto e assegnare un riferimento.

In fase di progettazione, la Designer SSIS esegue questa assegnazione durante il caricamento e l'inizializzazione di un componente. Tuttavia, quando si carica e si modifica un componente a livello di codice, usando il modello a oggetti all'esterno della finestra di progettazione, la proprietà deve essere impostata in modo esplicito. I componenti non hanno la possibilità di fare riferimento in modo esplicito alla connessione usando ConnectionManagerID la proprietà perché l'insieme Connections del pacchetto non è esposto ai componenti.

Si applica a