Get-SmbClientNetworkInterface
Retrieves the network interfaces used by the SMB client.
Syntax
Get-SmbClientNetworkInterface
[-CimSession <CimSession[]>]
[-ThrottleLimit <Int32>]
[-AsJob]
[<CommonParameters>]
Description
The Get-SmbClientNetworkInterface cmdlet retrieves the network interfaces used by the Server Message Block (SMB) client.
Examples
Example 1: Get network interfaces used by an SMB client
PS C:\>Get-SmbClientNetworkInterface
Interface Index RSS Capable RDMA Capable Speed IpAddresses Friendly Name
--------------- ----------- ------------ ----- ----------- -------------
12 True True 32 Gbps {192.168.101.13} RDMA1
15 True True 32 Gbps {192.168.102.13} RDMA2
17 False False 0 bps {fe80::5efe:192.... isatap.{EF722F0D...
18 False False 0 bps {fe80::5efe:192.... isatap.{BD3C4A04...
19 False False 0 bps {fe80::5efe:192.... isatap.{597B0A73...
20 False False 0 bps {fe80::6065:ddbf... Local Area Conne...
32 False False 10 Gbps {172.30.182.10} ExternalVirtual
16 False False 3 Gbps {2001:4898:0:fff... isatap.corp.cont...
14 False False 1 Gbps {192.168.100.13} Internal
This command retrieves the network interfaces used by the SMB client.
Example 2: Get network interfaces used by an SMB client for a specified link speed
PS C:\>Get-SmbClientNetworkInterface | Where-Object -Property LinkSpeed -Gt 10GB
Interface Index RSS Capable RDMA Capable Speed IpAddresses Friendly Name
--------------- ----------- ------------ ----- ----------- -------------
12 True True 32 Gbps {192.168.101.13} RDMA1
15 True True 32 Gbps {192.168.102.13} RDMA2
This command retrieves the network interfaces used by the SMB client that match the link speed of 10 gigabits or more.
Example 3: Display details for network interfaces
PS C:\>Get-SmbClientNetworkInterface | Where-Object -Property LinkSpeed -Gt 10GB | Select-Object -Property *
FriendlyName : RDMA1
InterfaceIndex : 12
IpAddresses : {192.168.101.13}
LinkSpeed : 32000000000
RdmaCapable : True
RssCapable : True
PSComputerName :
CimClass : ROOT/Microsoft/Windows/SMB:MSFT_SmbClientNetworkInterface
CimInstanceProperties : {FriendlyName, InterfaceIndex, IpAddresses, LinkSpeed...}
CimSystemProperties : Microsoft.Management.Infrastructure.CimSystemProperties
FriendlyName : RDMA2
InterfaceIndex : 15
IpAddresses : {192.168.102.13}
LinkSpeed : 32000000000
RdmaCapable : True
RssCapable : True
PSComputerName :
CimClass : ROOT/Microsoft/Windows/SMB:MSFT_SmbClientNetworkInterface
CimInstanceProperties : {FriendlyName, InterfaceIndex, IpAddresses, LinkSpeed...}
CimSystemProperties : Microsoft.Management.Infrastructure.CimSystemProperties
This command displays all of the information retrieved from the network interfaces used by the SMB client that match the link speed of 10 gigabits or more.
Parameters
-AsJob
Runs the cmdlet as a background job. Use this parameter to run commands that take a long time to complete.
Type: | SwitchParameter |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-CimSession
Runs the cmdlet in a remote session or on a remote computer. Enter a computer name or a session object, such as the output of a New-CimSession or Get-CimSession cmdlet. The default is the current session on the local computer.
Type: | CimSession[] |
Aliases: | Session |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-ThrottleLimit
Specifies the maximum number of concurrent operations that can be established to run the cmdlet.
If this parameter is omitted or a value of 0
is entered, then Windows PowerShell® calculates an optimum throttle limit for the cmdlet based on the number of CIM cmdlets that are running on the computer.
The throttle limit applies only to the current cmdlet, not to the session or to the computer.
Type: | Int32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Inputs
None
Outputs
The Microsoft.Management.Infrastructure.CimInstance
object is a wrapper class that displays Windows Management Instrumentation (WMI) objects.
The path after the pound sign (#
) provides the namespace and class name for the underlying WMI object.
This cmdlet returns a MSFT_SmbClientNetworkInterface object that represents the network interfaces used by the SMB client.