CreateSwitch method of the Msvm_VirtualSwitchManagementService class
Creates a new virtual switch.
Syntax
uint32 CreateSwitch(
[in] string Name,
[in] string FriendlyName,
[in] uint32 NumLearnableAddresses,
[in] string ScopeOfResidence,
[out] Msvm_VirtualSwitch REF CreatedVirtualSwitch
);
Parameters
-
Name [in]
-
Type: string
The name of the switch. This name must be unique to all virtual switches in the system.
-
FriendlyName [in]
-
Type: string
A user-readable name for the switch.
-
NumLearnableAddresses [in]
-
Type: uint32
The maximum number of MAC addresses that can be learned by the switch.
-
ScopeOfResidence [in]
-
Type: string
The initial scope of the switch.
-
CreatedVirtualSwitch [out]
-
Type: Msvm_VirtualSwitch
Upon successful completion of this method, this parameter contains the created switch. See Msvm_VirtualSwitch.
Return value
Type: uint32
The method returns 0 if it succeeded synchronously. Any other return value indicates an error.
-
Completed with No Error (0)
-
Method Parameters Checked - Job Started (4096)
-
Failed (32768)
-
Access Denied (32769)
-
Not Supported (32770)
-
Status is unknown (32771)
-
Timeout (32772)
-
Invalid parameter (32773)
-
System is in used (32774)
-
Invalid state for this operation (32775)
-
Incorrect data type (32776)
-
System is not available (32777)
-
Out of memory (32778)
Remarks
Access to the Msvm_VirtualSwitchManagementService class might be restricted by UAC Filtering. For more information, see User Account Control and WMI.
Examples
The following C# sample creates a virtual switch. The referenced utilities can be found in Common Utilities for the Virtualization Samples.
using System;
using System.Management;
namespace HyperVSamples
{
class CreateSwitchClass
{
static ManagementObject CreateSwitch(string name, string friendlyName, int learnableAddress)
{
ManagementScope scope = new ManagementScope(@"root\virtualization", null);
ManagementObject switchService = Utility.GetServiceObject(scope, "Msvm_VirtualSwitchManagementService");
ManagementObject createdSwitch = null;
ManagementBaseObject inParams = switchService.GetMethodParameters("CreateSwitch");
inParams["FriendlyName"] = friendlyName;
inParams["Name"] = name;
inParams["NumLearnableAddresses"] = learnableAddress;
inParams["ScopeofResidence"] = null;
ManagementBaseObject outParams = switchService.InvokeMethod("CreateSwitch", inParams, null);
if ((UInt32)outParams["ReturnValue"] == ReturnCode.Completed)
{
Console.WriteLine("{0} was created successfully", inParams["Name"]);
createdSwitch = new ManagementObject(outParams["CreatedVirtualSwitch"].ToString());
}
else
{
Console.WriteLine("Failed to create {0} switch.", inParams["Name"]);
}
return createdSwitch;
}
static void Main(string[] args)
{
if (args != null && args.Length != 3)
{
Console.WriteLine("Usage: CreateSwitch name friendlyName NumLearnableAddresses");
Console.WriteLine("Example: CreateSwitch FirstSwitch \"My First Switch\" 1024");
return;
}
CreateSwitch(args[0], args[1], int.Parse(args[2]));
}
}
}
The following VBScript sample creates a virtual switch.
option explicit
dim objWMIService
dim switchService
dim fileSystem
const wmiStarted = 4096
const wmiSuccessful = 0
Main()
'-----------------------------------------------------------------
' Main
'-----------------------------------------------------------------
Sub Main()
dim name, friendlyName, learnableAddress
dim computer, objArgs, createdSwitch
set objArgs = WScript.Arguments
if WScript.Arguments.Count = 3 then
name = objArgs.Unnamed.Item(0)
friendlyName = objArgs.Unnamed.Item(1)
learnableAddress = objArgs.Unnamed.Item(2)
else
WScript.Echo "usage: cscript CreateSwitch.vbs name friendlyName learnableAddress"
WScript.Echo "Example: CreateSwitch FirstSwitch ""My First Switch"" 1024"
WScript.Quit(1)
end if
set fileSystem = Wscript.CreateObject("Scripting.FileSystemObject")
computer = "."
set objWMIService = GetObject("winmgmts:\\" & computer & "\root\virtualization")
set switchService = objWMIService.ExecQuery("select * from Msvm_VirtualSwitchManagementService").ItemIndex(0)
set createdSwitch = CreateSwitch(name, friendlyName, learnableAddress)
if createdSwitch Is Nothing then
WriteLog "CreateSwitch failed."
WScript.Quit(1)
else
WriteLog "Done"
WScript.Quit(0)
end if
End Sub
'-----------------------------------------------------------------
' Create a virtual switch by calling CreateSwitch WMI method
'-----------------------------------------------------------------
Function CreateSwitch(name, friendlyName, learnableAddress)
dim objInParam, objOutParams
set CreateSwitch = Nothing
set objInParam = switchService.Methods_("CreateSwitch").InParameters.SpawnInstance_()
objInParam.FriendlyName = friendlyName
objInParam.Name = name
objInParam.NumLearnableAddresses = learnableAddress
objInParam.ScopeofResidence = null
set objOutParams = switchService.ExecMethod_("CreateSwitch", objInParam)
if objOutParams.ReturnValue = wmiSuccessful then
set CreateSwitch = objWMIService.Get(objOutParams.CreatedVirtualSwitch)
else
WriteLog Format1("CreateSwitch failed with error code {0}", objOutParams.ReturnValue)
end if
End Function
'-----------------------------------------------------------------
' Create the console log files.
'-----------------------------------------------------------------
Sub WriteLog(line)
dim fileStream
set fileStream = fileSystem.OpenTextFile(".\CreateSwitch.log", 8, true)
WScript.Echo line
fileStream.WriteLine line
fileStream.Close
End Sub
'------------------------------------------------------------------------------
' The string formatting functions to avoid string concatenation.
'------------------------------------------------------------------------------
Function Format1(myString, arg0)
Format1 = Replace(myString, "{0}", arg0)
End Function
Requirements
Minimum supported client |
None supported |
Minimum supported server |
Windows Server 2008 |
End of client support |
None supported |
End of server support |
Windows Server 2012 |
Namespace |
Root\Virtualization |
MOF |
|