편집

다음을 통해 공유


Disable-NetAdapterLso

Disables all LSO properties, such as LSOv4 and LSOv6, of the network adapter.

Syntax

Disable-NetAdapterLso
       [-Name] <String[]>
       [-IncludeHidden]
       [-IPv4]
       [-IPv6]
       [-NoRestart]
       [-PassThru]
       [-CimSession <CimSession[]>]
       [-ThrottleLimit <Int32>]
       [-AsJob]
       [-WhatIf]
       [-Confirm]
       [<CommonParameters>]
Disable-NetAdapterLso
       -InterfaceDescription <String[]>
       [-IncludeHidden]
       [-IPv4]
       [-IPv6]
       [-NoRestart]
       [-PassThru]
       [-CimSession <CimSession[]>]
       [-ThrottleLimit <Int32>]
       [-AsJob]
       [-WhatIf]
       [-Confirm]
       [<CommonParameters>]
Disable-NetAdapterLso
       -InputObject <CimInstance[]>
       [-IPv4]
       [-IPv6]
       [-NoRestart]
       [-PassThru]
       [-CimSession <CimSession[]>]
       [-ThrottleLimit <Int32>]
       [-AsJob]
       [-WhatIf]
       [-Confirm]
       [<CommonParameters>]

Description

The Disable-NetAdapterLso cmdlet disables the state of the large send offload (LSO) settings, such as LSOv4 and LSOv6, on the network adapter. If neither LSOv4 or LSOv6 is specified, then both are disabled. LSO is a technology in which the work of segmenting data into network frames is performed by the network adapter instead of by the TCP/IP stack. With LSO, TCP/IP sends very large data packets down to the network adapter driver and the network adapter hardware. The network adapter breaks up the data into smaller network-sized frames. This increases the speed of large packet send operations and decreases the processor usage of the computer, because the work is performed on the network adapter. To disable individual LSOv4 or LSOv6, run the Set-NetAdapterLso cmdlet.

Examples

Example 1: Disable LSO for IPv6 on a specified network adapter

PS C:\> Disable-NetAdapterLso -Name "MyAdapter" -IPv6

This command disables the LSO for IPv6 on the network adapter named MyAdapter and restarts the network adapter.

Parameters

-AsJob

Runs the cmdlet as a background job. Use this parameter to run commands that take a long time to complete. The cmdlet immediately returns an object that represents the job and then displays the command prompt. You can continue to work in the session while the job completes. To manage the job, use the *-Job cmdlets. To get the job results, use the Receive-Job cmdlet. For more information about Windows PowerShell® background jobs, see about_Jobs.

Type:SwitchParameter
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-CimSession

Runs the cmdlet in a remote session or on a remote computer. Enter a computer name or a session object, such as the output of a New-CimSession or Get-CimSession cmdlet. The default is the current session on the local computer.

Type:CimSession[]
Aliases:Session
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-Confirm

Prompts you for confirmation before running the cmdlet.

Type:SwitchParameter
Aliases:cf
Position:Named
Default value:False
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-IncludeHidden

Indicates that the cmdlet includes both visible and hidden network adapters in the operation. By default only visible network adapters are included. If a wildcard character is used in identifying a network adapter and this parameter has been specified, then the wildcard string is matched against both hidden and visible network adapters.

Type:SwitchParameter
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-InputObject

Specifies the input to this cmdlet. You can use this parameter, or you can pipe the input to this cmdlet.

Type:CimInstance[]
Position:Named
Default value:None
Required:True
Accept pipeline input:True
Accept wildcard characters:False

-InterfaceDescription

Specifies an array of network adapter interface descriptions. For a physical network adapter this is typically the name of the vendor of the network adapter followed by a part number and description, such as Contoso 12345 Gigabit Network Device.

Type:String[]
Aliases:ifDesc, InstanceID
Position:Named
Default value:None
Required:True
Accept pipeline input:True
Accept wildcard characters:False

-IPv4

Indicates that the cmdlet affects IPv4 traffic.

Type:SwitchParameter
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-IPv6

Indicates that the cmdlet affects IPv6 traffic.

Type:SwitchParameter
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-Name

Specifies an array of network adapter names.

Type:String[]
Aliases:ifAlias, InterfaceAlias
Position:0
Default value:None
Required:True
Accept pipeline input:True
Accept wildcard characters:False

-NoRestart

Indicates that the cmdlet does not restart the network adapter after completing the operation. Many advanced properties require restarting the network adapter before the new settings take effect.

Type:SwitchParameter
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-PassThru

Returns an object representing the item with which you are working. By default, this cmdlet does not generate any output.

Type:SwitchParameter
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-ThrottleLimit

Specifies the maximum number of concurrent operations that can be established to run the cmdlet. If this parameter is omitted or a value of 0 is entered, then Windows PowerShell® calculates an optimum throttle limit for the cmdlet based on the number of CIM cmdlets that are running on the computer. The throttle limit applies only to the current cmdlet, not to the session or to the computer.

Type:Int32
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-WhatIf

Shows what would happen if the cmdlet runs. The cmdlet is not run.

Type:SwitchParameter
Aliases:wi
Position:Named
Default value:False
Required:False
Accept pipeline input:False
Accept wildcard characters:False

Inputs

CimInstance[]

The Microsoft.Management.Infrastructure.CimInstance object is a wrapper class that displays Windows Management Instrumentation (WMI) objects. The path after the pound sign (#) provides the namespace and class name for the underlying WMI object.

Outputs

CimInstance

The Microsoft.Management.Infrastructure.CimInstance object is a wrapper class that displays Windows Management Instrumentation (WMI) objects. The path after the pound sign (#) provides the namespace and class name for the underlying WMI object.